PDUs for ASIC miners

Power distribution units for racks of miners, with input voltage and current, outlets and breaker protection as published.

Listed
3
In stock
1
From
$320
Bitmain ANTPDU PW12V1

All PDUs we list

Main specs, the models each one fits, and price or quote.

  • In stock

    Bitmain

    Bitmain ANTPDU PW12V1

    Input breaker
    100 A 3-pole
    Input voltage (V)
    346-480 AC, 3P+N+PE
    Frequency (Hz)
    50/60

    $320

    Fits 2 models

    View specs
  • Raptor Power Systems

    Raptor Crypto Minotaur PDU

    Outlets
    24 x C19, 20 A each
    Branch protection
    12 banks of 50 A breakers…

    Price on request

    View specs
  • Raptor Power Systems

    Raptor Crypto Slayer 3.0 PDU

    Phase
    three
    Miners powered
    12
    Total power (kW)
    46

    Price on request

    View specs

How to choose

  • Input and outlets

    Match the PDU’s input plug and voltage to your supply, and count its outlets against the machines it will feed.

  • Current per circuit

    Add up the draw of every miner on the PDU and keep the total under the circuit rating, with margin.

  • Metering and switching

    Metered or switched outlets let you read each machine’s draw and restart one remotely.

Work out the load

Divide the watts on each miner’s page by your voltage to get its amps: 3,500 W at 240 V is 14.6 A. Add up the machines on each bank of outlets and keep each bank, and the PDU as a whole, within its continuous rating.

Single phase or three phase

On a three-phase supply of 415 V between phases, each outlet sees about 240 V between one phase and neutral, and each phase carries a third of the machines. Spread them evenly so no phase carries more than its share.

Where it sits

Leave room behind the rack for cords to bend, keep the PDU out of the hot exhaust, and label each outlet with its machine, so a breaker that trips points at one circuit instead of the whole rack.

Before you order

  1. 1

    Check the part number on the part you are replacing; revisions within one model can differ.

  2. 2

    Prices include delivery to your door. Your invoice shows every line.

Need more than one, or a part we do not list?

Send the model and the part number. A person replies with price, stock and a dispatch date.

Request a quote Repair service

Questions about PDUs

Ask us something else
  • How much do PDUs cost?

    Prices listed here start at $320 with delivery included.

  • How many miners fit on one PDU?

    As many as its outlets and its current rating allow: add each miner’s draw at your voltage and keep the total below the rating.

  • Do I need three-phase power?

    For large fleets it is common, and three-phase PDUs spread the load across the phases. Small sites run on single phase.

  • What is the 80% rule for a PDU?

    A miner is a continuous load, so in the United States its circuit is loaded to no more than 80% of the breaker. A 30 A breaker carries 24 A all day, which at 240 V is 5,760 W; a 50 A breaker carries 40 A, or 9,600 W.

  • C13 or C19 outlets?

    Look at the inlet on the machine’s power supply. C13 outlets are rated for less current than C19, so larger power supplies use C19 or a fixed connector. A supply with two inlets needs both connected.

  • Is a PDU the same as a power strip?

    No. A rack PDU is built for a continuous load, takes a higher voltage and a locking plug or fixed wiring, and protects its outlets in banks with their own breakers.