ASIC miner error codes

Type the code or log message to see what it means and how to fix it.

Codes by maker

Antminer 28 codes

All Antminer codes
Antminer error codes
Code What it means Fault
over max temp Chip over maximum temperature Overheating
PCB temp too high Board surface temperature too high Overheating
ERROR_FAN_LOST: fan X speed 0 rpm Fan lost (0 rpm) Fans
fan X speed below threshold Fan speed below threshold Fans
Chain[X] only has Y chips Chain reports fewer chips than expected Hashboards
check_asic_number_with_power_on: Chain[X] find 0 asic Chain finds 0 ASIC chips Hashboards
chip X disabled Chip removed from work Hashboards
EEPROM read failed Hashboard EEPROM cannot be read Hashboards
fail to read pic temp for chain X Cannot read temperature through the board PIC Hashboards
No hashboard found No hashboard found on any chain Hashboards
nonce error Invalid result from a chip Hashboards
pic heart beat lost chain X PIC heartbeat lost Hashboards
temp sensor read failed Hashboard temperature sensor read failed Hashboards
voltage domain error on chain X Voltage domain error Hashboards
ERROR_POWER_LOST: get power type version failed! Power lost / PSU type read failed Power supply
power fault Power fault / V_IN abnormal Power supply
power voltage can not meet the need of this bitmain equipment Power voltage does not meet the equipment's need Power supply
power voltage can not meet the target Power voltage cannot meet the target Power supply
ERROR_SOC_INIT: soc init failed! SoC initialisation failed Control board
Kernel panic - not syncing Kernel panic Control board
Unable to mount root fs Root filesystem cannot be mounted Control board
DNS resolve failed Pool hostname cannot be resolved Network and pool
socket connect failed Cannot open connection to pool Network and pool
Stratum connection interrupted Pool session dropped Network and pool
cgminer not running Mining process not running Firmware
chip bin not found Chip bin data not found Firmware
No space left on device Filesystem full Firmware
pic version mismatch PIC firmware version mismatch Firmware
Show all 28 Antminer codes

Avalon 9 codes

All Avalon codes
Avalon error codes
Code What it means Fault
PVT_T above 85 C Chip temperature in shutdown range Overheating
PS bit 2048 (FAN_error) PSU status flag FAN_error Fans
ASICCRC ASIC CRC error Hashboards
E: no asics!! No ASICs found Hashboards
PVT_V drift beyond 40 mV Domain voltage drift Hashboards
SYSTEMSTATU[0] Work < 3 Hashboard enumeration incomplete Hashboards
PS bit 1 (Input_UV) PSU status flag input under-voltage Power supply
PS[0..2] = 0 PSU telemetry reads zero Power supply
BOOTBY Reboot cause code Control board

Goldshell 2 codes

All Goldshell codes
Goldshell error codes
Code What it means Fault
pool not ready Pool not ready / connection failed Network and pool
CPBO failed to startup Core mining process failed to start Firmware

IceRiver 14 codes

All IceRiver codes
IceRiver error codes
Code What it means Fault
233-239 Over-temperature warnings Overheating
350-352 Hashboard overheat protection Overheating
110/111 Fan speed low Fans
120/121 Fan stalled Fans
140 Fan overspeed Fans
300 Temperature sensor no reading Hashboards
301 Temperature sensor stuck high Hashboards
302 Temperature sensor stuck low Hashboards
710 No reply from hashboard Control board
711 Hashboard reply failed integrity check Control board
712 Only some chips respond Control board
800 Firmware flash failed Firmware
801 Corrupt or mismatched firmware image Firmware
802 Connection dropped during firmware transfer Firmware
Show all 14 IceRiver codes

WhatsMiner 43 codes

All WhatsMiner codes
WhatsMiner error codes
Code What it means Fault
350-352 Hashboard high-temperature protection Overheating
600 Environment temperature too high Overheating
610 Too hot for high-performance mode Overheating
5070-5072 Water velocity abnormal (hydro) Overheating
110 Intake fan speed signal error Fans
111 Outlet fan speed signal error Fans
140 Fan speed too high Fans
300 SM0 temperature sensor detect fail Hashboards
301 SM1 temperature sensor fail Hashboards
302 SM2 temperature sensor fail Hashboards
410-412 Hashboard EEPROM read error Hashboards
510-512 Miner type error (hashboard model mismatch) Hashboards
530-532 Hashboard not found on scan Hashboards
540-542 Chip ID read error Hashboards
550-552 Bad chips detected Hashboards
560-562 Hashboard loss of balance Hashboards
5110-5112 Frequency ramp-up timed out Hashboards
200 Power probing error, no power found Power supply
202 Power output voltage error Power supply
205 Power current error Power supply
206 Low input voltage Power supply
218 Input below 230 V in high-performance mode Power supply
235 Power output over-temperature protection Power supply
240 PSU output under-voltage protection Power supply
263 PSU communication warning Power supply
264 PSU communication error Power supply
268 Power output over-current protection Power supply
270 Input over-voltage protection Power supply
271 Input under-voltage protection Power supply
272 Power output too high (warning) Power supply
275 PSU over-temperature warning Power supply
701 Control board does not support the chips Control board
710 Control board rebooted on exception Control board
714 Network connection unstable Network and pool
2000 No pool configured Network and pool
2010 All pools disabled Network and pool
2020 Pool 1 connection failed (shown as Pool0) Network and pool
2021 Pool 2 connection failed (shown as Pool1) Network and pool
2022 Pool 3 connection failed (shown as Pool2) Network and pool
2040 ASICBoost not supported by pool Network and pool
800-802 Firmware checksum error Firmware
810 Cooling or frequency setting does not match Firmware
8410 Wrong firmware for model Firmware
Show all 43 WhatsMiner codes

Error code questions

What does a hashboard error mean?

The control board reads fewer hashboards or chips than it expects. Reseating a data cable or the board’s power often fixes it; if it stays, our repair team takes over.

Why does my miner keep restarting?

Restart loops usually come from heat protection, an unstable power supply or a board that fails its start-up check. Check intake air and power first, then look in the log for the board number.

Is a factory reset safe?

Yes. A reset restores stock settings and does not touch the hardware. Note your pool details first, because you will need to enter them again.

My code is not listed. What now?

Search the exact log line on our site search, or send it to us with the model. We add new codes as owners report them.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.