Antminer check_asic_number_with_power_on: Chain[X] find 0 asic Chain finds 0 ASIC chips

The control board detects no chips on a hashboard chain and powers that board off; the log may continue with "will power off hash board X". The miner then runs on its remaining boards. Expected counts are 76 chips per chain for S19, S19 Pro and S19j Pro, 110 for S19 XP and 77 for S19k Pro.

Also shows as
Chain[X] only has Y chips · No hashboard found · power voltage can not meet the need of this bitmain equipment
Seen on
S19 family, S9, S21

How to fix it

Before you start. Power off and unplug the miner before you reseat any cable. Write down which chain number the log names, so you can tell whether the fault follows the board or stays with the slot when you swap cables.

  1. Power off at the breaker, wait 60 seconds, power on.

  2. Save the status page and kernel log and note which chain fails.

  3. Check intake air is under 35 C and nothing blocks the grille; cold-boot again.

  4. Check the PSU status light; a fault light means a PSU trip.

  5. Try the current official firmware.

  6. With power off, reseat the data ribbon and board power leads (case open: check warranty first).

  7. Swap the board into another slot: if the fault follows the board, the board needs repair.

  8. Try a known-good PSU of the same model.

  9. If the board is at fault, stop and send it for repair.

Likely causes

  1. Transient fault after a power event
  2. Overheating during start-up
  3. Failing PSU that starves the boards at start-up
  4. Loose or damaged data ribbon or board power lead
  5. Hashboard fault such as a boost converter, regulator or dead chip
  6. Corrupted hashboard EEPROM
  7. Control board slot fault

When to stop

Stop if the same board fails after you have reseated its cables and checked its power. Chip and board faults need a repair bench; do not open the board yourself if the machine is still under warranty.

Contact support

Read it, fix it, claim it

Where to read the code

Open the miner’s IP address in a browser, sign in, choose System, then Kernel Log. While the fault is showing, read the current log; once the miner runs again, look in the history log. If you do not know the address, start Bitmain’s IP Reporter on a computer on the same network and press the IP Report button on the control board.

How to know it is fixed

Every board should show its full chip count and a similar hashrate, and the average at your pool should return to the rated figure. A board that drops out again within a day has not been fixed by the restart.

When to claim warranty

Hardware fault. If the unit is inside the maker's warranty term, open a repair ticket after the outside-the-case checks and before opening the case or replacing parts: opening the unit, mixing boards, non-original parts or non-stock firmware can make the repair chargeable or refused.

Warranty and claims

Models this code affects

Setup guides for the Antminer models that show this code.

Questions about Antminer “check_asic_number_with_power_on: Chain[X] find 0 asic”

Will the miner still earn with Antminer “check_asic_number_with_power_on: Chain[X] find 0 asic”?

Often yes, with the boards that still work: a three-board miner that loses one runs at about two thirds of its hashrate. Some models stop altogether. Check what your pool receives.

Can a hashboard be repaired?

Yes, by a repair bench that can test and replace single chips. While the maker’s warranty runs, go to the maker first: an opened board can end the cover.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.