Antminer error codes

Every Antminer code we cover, grouped by fault, with causes and fixes.

Antminer codes by fault

Antminer error codes
Code What it means
Overheating
over max temp Chip over maximum temperature
PCB temp too high Board surface temperature too high
Fans
ERROR_FAN_LOST: fan X speed 0 rpm Fan lost (0 rpm)
fan X speed below threshold Fan speed below threshold
Hashboards
Chain[X] only has Y chips Chain reports fewer chips than expected
check_asic_number_with_power_on: Chain[X] find 0 asic Chain finds 0 ASIC chips
chip X disabled Chip removed from work
EEPROM read failed Hashboard EEPROM cannot be read
fail to read pic temp for chain X Cannot read temperature through the board PIC
No hashboard found No hashboard found on any chain
nonce error Invalid result from a chip
pic heart beat lost chain X PIC heartbeat lost
temp sensor read failed Hashboard temperature sensor read failed
voltage domain error on chain X Voltage domain error
Power supply
ERROR_POWER_LOST: get power type version failed! Power lost / PSU type read failed
power fault Power fault / V_IN abnormal
power voltage can not meet the need of this bitmain equipment Power voltage does not meet the equipment's need
power voltage can not meet the target Power voltage cannot meet the target
Control board
ERROR_SOC_INIT: soc init failed! SoC initialisation failed
Kernel panic - not syncing Kernel panic
Unable to mount root fs Root filesystem cannot be mounted
Network and pool
DNS resolve failed Pool hostname cannot be resolved
socket connect failed Cannot open connection to pool
Stratum connection interrupted Pool session dropped
Firmware
cgminer not running Mining process not running
chip bin not found Chip bin data not found
No space left on device Filesystem full
pic version mismatch PIC firmware version mismatch

Where a Antminer shows its code

Open the miner’s IP address in a browser, sign in, choose System, then Kernel Log. While the fault is showing, read the current log; once the miner runs again, look in the history log. If you do not know the address, start Bitmain’s IP Reporter on a computer on the same network and press the IP Report button on the control board.

What to check first

Most Antminer faults come from heat, power, fans or the network rather than the chips. Check intake air, input voltage, fan speeds and the pool settings first, and keep the Bitmain stock firmware while you test, so a warranty claim stays open.

Antminer error codes: common questions

How do I clear a Antminer error code?

Fix the cause, then restart the miner once: the code goes when the fault does. Write down the code, the board number and what the miner was doing before you restart, as the log may start again.

Is it safe to keep mining with an error showing?

A network or pool message is harmless and the miner picks up again by itself. With a temperature, fan or power message, switch off first and look for the cause.

What should I send with a warranty claim to Bitmain?

The serial number, the code, a photo or copy of the log, the firmware version and what you have tried. A claim with all five usually needs no second round.

Can you repair or replace the part for me?

Yes. Send us the model and the code. We tell you whether a spare part, a repair or a claim with Bitmain is the quickest way back to mining.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.