Antminer error codes
Every Antminer code we cover, grouped by fault, with causes and fixes.
Antminer codes by fault
No code matches that
Check the spelling or try fewer words. The site search also covers guides and models.
| Code | What it means |
|---|---|
| Overheating | |
| over max temp | Chip over maximum temperature |
| PCB temp too high | Board surface temperature too high |
| Fans | |
| ERROR_FAN_LOST: fan X speed 0 rpm | Fan lost (0 rpm) |
| fan X speed below threshold | Fan speed below threshold |
| Hashboards | |
| Chain[X] only has Y chips | Chain reports fewer chips than expected |
| check_asic_number_with_power_on: Chain[X] find 0 asic | Chain finds 0 ASIC chips |
| chip X disabled | Chip removed from work |
| EEPROM read failed | Hashboard EEPROM cannot be read |
| fail to read pic temp for chain X | Cannot read temperature through the board PIC |
| No hashboard found | No hashboard found on any chain |
| nonce error | Invalid result from a chip |
| pic heart beat lost chain X | PIC heartbeat lost |
| temp sensor read failed | Hashboard temperature sensor read failed |
| voltage domain error on chain X | Voltage domain error |
| Power supply | |
| ERROR_POWER_LOST: get power type version failed! | Power lost / PSU type read failed |
| power fault | Power fault / V_IN abnormal |
| power voltage can not meet the need of this bitmain equipment | Power voltage does not meet the equipment's need |
| power voltage can not meet the target | Power voltage cannot meet the target |
| Control board | |
| ERROR_SOC_INIT: soc init failed! | SoC initialisation failed |
| Kernel panic - not syncing | Kernel panic |
| Unable to mount root fs | Root filesystem cannot be mounted |
| Network and pool | |
| DNS resolve failed | Pool hostname cannot be resolved |
| socket connect failed | Cannot open connection to pool |
| Stratum connection interrupted | Pool session dropped |
| Firmware | |
| cgminer not running | Mining process not running |
| chip bin not found | Chip bin data not found |
| No space left on device | Filesystem full |
| pic version mismatch | PIC firmware version mismatch |
Where a Antminer shows its code
Open the miner’s IP address in a browser, sign in, choose System, then Kernel Log. While the fault is showing, read the current log; once the miner runs again, look in the history log. If you do not know the address, start Bitmain’s IP Reporter on a computer on the same network and press the IP Report button on the control board.
What to check first
Most Antminer faults come from heat, power, fans or the network rather than the chips. Check intake air, input voltage, fan speeds and the pool settings first, and keep the Bitmain stock firmware while you test, so a warranty claim stays open.
Antminer error codes: common questions
How do I clear a Antminer error code?
Fix the cause, then restart the miner once: the code goes when the fault does. Write down the code, the board number and what the miner was doing before you restart, as the log may start again.
Is it safe to keep mining with an error showing?
A network or pool message is harmless and the miner picks up again by itself. With a temperature, fan or power message, switch off first and look for the cause.
What should I send with a warranty claim to Bitmain?
The serial number, the code, a photo or copy of the log, the firmware version and what you have tried. A claim with all five usually needs no second round.
Can you repair or replace the part for me?
Yes. Send us the model and the code. We tell you whether a spare part, a repair or a claim with Bitmain is the quickest way back to mining.