Antminer power voltage can not meet the need of this bitmain equipment Power voltage does not meet the equipment's need

Shown alongside a chain that finds 0 chips: the board is not getting enough power during start-up.

How to fix it

Before you start. Have the input voltage measured at the socket while the miner runs. Never open a power supply: its capacitors hold a dangerous charge after it is switched off.

  1. Power off at the breaker and restart.

  2. Confirm the supply voltage and PSU model.

  3. Try a known-good PSU.

  4. If the chain is still not detected, treat as a hashboard fault.

Likely causes

  1. Failing PSU
  2. Low input voltage
  3. Loose board power lead

When to stop

Stop if the supply faults on a circuit that measures in spec under load, or if it smells burnt or clicks. Replace the power supply or claim it under warranty.

Contact support

Read it, fix it, claim it

Where to read the code

Open the miner’s IP address in a browser, sign in, choose System, then Kernel Log. While the fault is showing, read the current log; once the miner runs again, look in the history log. If you do not know the address, start Bitmain’s IP Reporter on a computer on the same network and press the IP Report button on the control board.

How to know it is fixed

Let it run at full load for an hour and look for the code again. Have the voltage at the socket measured while it runs: a supply that is in range with the machine off can still drop under load.

When to claim warranty

If the error stays with a correct, stable supply and stock settings, it points at the PSU or a hashboard: claim under warranty while in term. Damage from wrong voltage, surges or unstable power is excluded by most makers, so keep your voltage readings and logs as evidence.

Warranty and claims

Questions about Antminer “power voltage can not meet the need of this bitmain equipment”

Is Antminer “power voltage can not meet the need of this bitmain equipment” the power supply or my wiring?

Try the machine on a circuit that is known to be good, or a machine that works on this circuit. If the fault stays with the circuit, call an electrician. If it follows the machine, look at the supply.

Can I fit any power supply with enough watts?

No. The output voltage, the connectors and the data link have to match the model. Our power supply pages list the miners each one fits.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.