Antminer ERROR_POWER_LOST: get power type version failed! Power lost / PSU type read failed
The control board reports a power problem, often wrong input voltage. S19-family PSUs (APW12, APW171, APW191) need 200 to 240 V and cannot run on a 110/120 V household circuit. It can appear even while the PSU fan spins.
- Also shows as
- power voltage can not meet the target
- Seen on
- S19 family, S21
How to fix it
Before you start. Have the input voltage measured at the socket while the miner runs. Never open a power supply: its capacitors hold a dangerous charge after it is switched off.
Stop mining and unplug if the unit is on 120 V.
Confirm the outlet and breaker supply 240 V (a licensed electrician should install a dedicated circuit if none exists).
Save the kernel log.
With power off, inspect the PSU signal cable for bent or corroded pins.
Try a known-good PSU of the same model.
Reflash stock firmware if the error stays on a correct supply.
Likely causes
- Miner on a 120 V outlet
- PSU damaged by running on low voltage
- Damaged PSU-to-control-board signal cable
- Control board power flag stuck after a power event
When to stop
Stop if the supply faults on a circuit that measures in spec under load, or if it smells burnt or clicks. Replace the power supply or claim it under warranty.
Contact supportRead it, fix it, claim it
Where to read the code
Open the miner’s IP address in a browser, sign in, choose System, then Kernel Log. While the fault is showing, read the current log; once the miner runs again, look in the history log. If you do not know the address, start Bitmain’s IP Reporter on a computer on the same network and press the IP Report button on the control board.
How to know it is fixed
Let it run at full load for an hour and look for the code again. Have the voltage at the socket measured while it runs: a supply that is in range with the machine off can still drop under load.
When to claim warranty
If the error stays with a correct, stable supply and stock settings, it points at the PSU or a hashboard: claim under warranty while in term. Damage from wrong voltage, surges or unstable power is excluded by most makers, so keep your voltage readings and logs as evidence.
Warranty and claimsModels this code affects
Setup guides for the Antminer models that show this code.
Questions about Antminer “ERROR_POWER_LOST: get power type version failed!”
Is Antminer “ERROR_POWER_LOST: get power type version failed!” the power supply or my wiring?
Try the machine on a circuit that is known to be good, or a machine that works on this circuit. If the fault stays with the circuit, call an electrician. If it follows the machine, look at the supply.
Can I fit any power supply with enough watts?
No. The output voltage, the connectors and the data link have to match the model. Our power supply pages list the miners each one fits.