How to set up the Antminer S19 Pro+ Hyd

Power, network and pool steps for the Antminer S19 Pro+ Hyd, in order.

Bitmain Antminer S19 Pro+ Hyd

What you need

Input voltage
342–418 V
Power draw
5,445 W
Room temperature
0 to 40 °C
Inlet water
20 to 40 °C
Network
RJ45 Ethernet 10/100M

Setup steps

  1. Connect the cooling loop

    Connect and fill the cooling loop, and check for leaks before you power on. Check every joint for leaks and bleed the air out of the loop first. The flow has to be steady before the machine gets power, because the chips heat up within seconds.

  2. Wire the power

    It needs 342–418 V and draws 5,445 W. Use a dedicated circuit sized for that load.

  3. Connect the network

    Plug it into your router or switch with a network cable, then find its IP address in the router or the maker's IP tool. A fixed address helps: reserve one for the machine in your router, so the same address opens it after a restart. No port has to be opened to the internet.

  4. Point it at a pool

    Open its dashboard and enter your Bitcoin pool address, worker name and password. Most pools write the worker as account.worker; solo pools often take your wallet address instead. Enter a second pool as a backup, change the default password of the dashboard, and save.

  5. Check it is hashing

    After a few minutes, check that hashrate, temperatures and fan speeds look normal. The pool shows the worker within a few minutes. Judge the hashrate by the pool’s 24-hour average, because the figure over minutes swings with luck. Write down the normal temperatures, so you notice later when they change.

Versions of the Antminer S19 Pro+ Hyd

Versions of the Antminer S19 Pro+ Hyd
Version Hashrate Power
Antminer S19 Pro+ Hyd 198 TH/s 198 TH/s 5,445 W
Antminer S19 Pro+ Hyd 191 TH/s 191 TH/s 5,253 W
Antminer S19 Pro+ Hyd 184 TH/s 184 TH/s 5,060 W
Antminer S19 Pro+ Hyd 177 TH/s 177 TH/s 4,868 W
Antminer S19 Pro+ Hyd 170 TH/s 170 TH/s 4,675 W

Antminer S19 Pro+ Hyd setup questions

How much power does the Antminer S19 Pro+ Hyd use?

The Antminer S19 Pro+ Hyd draws 5,445 W on 342–418 V. Running all day, that is about 130.7 kWh of electricity every 24 hours.

What circuit does the Antminer S19 Pro+ Hyd need?

A dedicated circuit. At 418 V it draws about 13.0 A, so with the 80 percent rule for loads that run for hours it needs at least a 20 A breaker, with cable rated to match. Have a licensed electrician confirm it for your site.

How does the Antminer S19 Pro+ Hyd connect to the internet?

Through RJ45 Ethernet 10/100M. Once it is connected, find its IP address in your router and open that address in a browser on the same network to reach its dashboard.

What water temperature does the Antminer S19 Pro+ Hyd need?

The maker rates the inlet water at 20 to 40 °C. Keep the loop within that range before and during mining.

What hashrate should the Antminer S19 Pro+ Hyd show?

Between 170 TH/s and 198 TH/s as an average over a day, depending on the version you have. The label on the machine names it; a lasting drop of a tenth or more points at heat, power or one hashboard.

How much heat does the Antminer S19 Pro+ Hyd give off?

All the power it draws leaves it as heat: 5,445 W is about 18,600 BTU an hour. Plan the ventilation or cooling of the room for that, all day.

What does the Antminer S19 Pro+ Hyd cost to run?

Its 5,445 W use about 3,920 kWh in 30 days. Multiply that by the price per kWh on your power bill: at $0.10 it is about $392, at $0.20 about $784. Hosted with us it is about $290 at $0.074, for 10–49 machines.

What does the Antminer S19 Pro+ Hyd mine?

It mines Bitcoin on the SHA-256 algorithm. Point it at a pool for that coin with your own payout address.

Rather not run it yourself?