Antminer over max temp Chip over maximum temperature
A chip temperature sensor read above the firmware limit and hashing stopped. Typical warning and shutdown chip temperatures: S9 85/95 C, S17 80/90 C, S19 80/90 C, S21 85/95 C.
- Also shows as
- ERROR_TEMP_TOO_HIGH
- Seen on
- S9, S17, S19, S21
How to fix it
Before you start. Note the intake air temperature and the chip and board readings on the status page before you change anything. Overheating is almost always about the room or the airflow, so fix those first and leave the machine’s settings for last.
Power off and let the miner cool for 15 to 30 minutes.
Check room temperature (keep it below 30 C) and the clearance around the unit.
With power off, clean fans and heatsinks.
Confirm all fans report normal speed after restart.
Return to stock clocks.
If it trips again with good airflow, send the unit for inspection.
Likely causes
- High room temperature
- Blocked airflow
- Failed fan
- Degraded thermal paste
- Overclocking
- Faulty sensor
When to stop
Stop if one board keeps running far hotter than the others with clean fans and cool intake air, or if you see scorching on the board. That points at the board itself, and opening it can void the warranty.
Contact supportRead it, fix it, claim it
Where to read the code
Open the miner’s IP address in a browser, sign in, choose System, then Kernel Log. While the fault is showing, read the current log; once the miner runs again, look in the history log. If you do not know the address, start Bitmain’s IP Reporter on a computer on the same network and press the IP Report button on the control board.
How to know it is fixed
Run at full load for an hour and watch the intake, board and chip readings. They should settle and stay level, not creep up. Look again in the hottest part of the day.
When to claim warranty
Overheating caused by room air, dust or blocked airflow is not a defect. Claim if the same board or sensor still faults with intake air in spec, clean working fans and stock settings.
Warranty and claimsModels this code affects
Setup guides for the Antminer models that show this code.
Questions about Antminer “over max temp”
Can I keep mining with Antminer “over max temp”?
Not for long. A miner that is too hot slows down or stops itself to protect its chips, so it earns less than it should until the heat is gone. Raising a temperature limit hides the warning and leaves the heat.
Is it the room or the machine?
Compare the boards. If all of them read high, look at the room, the dust and the airflow. If one reads far above the rest with the same air, look at that board or its sensor.