How to set up the Antminer S17+
Power, network and pool steps for the Antminer S17+, in order.
What you need
- Input voltage
- 200–240 V
- Power draw
- 3,040 W
- Current
- 18.3 A
- Room temperature
- 0 to 40 °C
- Noise
- 82 dB
- Network
- RJ45 Ethernet 10/100M
Setup steps
-
Place it with cool air
Pick a dry, clean spot where hot exhaust cannot loop back to the intake. It runs in 0 to 40 °C. Leave free space at the front and the back, and lead the warm air out of the room. Do not stack machines directly on each other.
-
Wire the power
It needs 200–240 V, draws 3,040 W and up to 18.3 A. Use a dedicated circuit sized for that load. Use a cord rated for that current, push every plug fully in, and connect all inlets when the machine has more than one. Have a licensed electrician add a circuit where none fits.
-
Connect the network
Plug it into your router or switch with a network cable, then find its IP address in the router or the maker's IP tool. A fixed address helps: reserve one for the machine in your router, so the same address opens it after a restart. No port has to be opened to the internet.
-
Point it at a pool
Open its dashboard and enter your Bitcoin pool address, worker name and password. Most pools write the worker as account.worker; solo pools often take your wallet address instead. Enter a second pool as a backup, change the default password of the dashboard, and save.
-
Check it is hashing
After a few minutes, check that hashrate, temperatures and fan speeds look normal. The pool shows the worker within a few minutes. Judge the hashrate by the pool’s 24-hour average, because the figure over minutes swings with luck. Write down the normal temperatures, so you notice later when they change.
Versions of the Antminer S17+
| Version | Hashrate | Power |
|---|---|---|
|
|
76 TH/s | 3,040 W |
|
|
73 TH/s | 2,920 W |
|
|
70 TH/s | 2,800 W |
|
|
67 TH/s | 2,680 W |
Antminer S17+ setup questions
How much power does the Antminer S17+ use?
The Antminer S17+ draws 3,040 W on 200–240 V. Running all day, that is about 73.0 kWh of electricity every 24 hours.
What circuit does the Antminer S17+ need?
A dedicated circuit. At 240 V it draws about 12.7 A, so with the 80 percent rule for loads that run for hours it needs at least a 20 A breaker, with cable rated to match. Have a licensed electrician confirm it for your site.
How does the Antminer S17+ connect to the internet?
Through RJ45 Ethernet 10/100M. Once it is connected, find its IP address in your router and open that address in a browser on the same network to reach its dashboard.
What room temperature does the Antminer S17+ need?
The maker rates it for 0 to 40 °C. Keep the hot exhaust away from the intake, because air that loops back raises chip temperatures and can trigger a shutdown.
What hashrate should the Antminer S17+ show?
Between 67 TH/s and 76 TH/s as an average over a day, depending on the version you have. The label on the machine names it; a lasting drop of a tenth or more points at heat, power or one hashboard.
How much heat does the Antminer S17+ give off?
All the power it draws leaves it as heat: 3,040 W is about 10,400 BTU an hour. Plan the ventilation or cooling of the room for that, all day.
What does the Antminer S17+ cost to run?
Its 3,040 W use about 2,189 kWh in 30 days. Multiply that by the price per kWh on your power bill: at $0.10 it is about $219, at $0.20 about $438. Hosted with us it is about $162 at $0.074, for 10–49 machines.
What does the Antminer S17+ mine?
It mines Bitcoin on the SHA-256 algorithm. Point it at a pool for that coin with your own payout address.