WhatsMiner error codes

Every WhatsMiner code we cover, grouped by fault, with causes and fixes.

WhatsMiner codes by fault

WhatsMiner error codes
Code What it means
Overheating
350-352 Hashboard high-temperature protection
600 Environment temperature too high
610 Too hot for high-performance mode
5070-5072 Water velocity abnormal (hydro)
Fans
110 Intake fan speed signal error
111 Outlet fan speed signal error
140 Fan speed too high
Hashboards
300 SM0 temperature sensor detect fail
301 SM1 temperature sensor fail
302 SM2 temperature sensor fail
410-412 Hashboard EEPROM read error
510-512 Miner type error (hashboard model mismatch)
530-532 Hashboard not found on scan
540-542 Chip ID read error
550-552 Bad chips detected
560-562 Hashboard loss of balance
5110-5112 Frequency ramp-up timed out
Power supply
200 Power probing error, no power found
202 Power output voltage error
205 Power current error
206 Low input voltage
218 Input below 230 V in high-performance mode
235 Power output over-temperature protection
240 PSU output under-voltage protection
263 PSU communication warning
264 PSU communication error
268 Power output over-current protection
270 Input over-voltage protection
271 Input under-voltage protection
272 Power output too high (warning)
275 PSU over-temperature warning
Control board
701 Control board does not support the chips
710 Control board rebooted on exception
Network and pool
714 Network connection unstable
2000 No pool configured
2010 All pools disabled
2020 Pool 1 connection failed (shown as Pool0)
2021 Pool 2 connection failed (shown as Pool1)
2022 Pool 3 connection failed (shown as Pool2)
2040 ASICBoost not supported by pool
Firmware
800-802 Firmware checksum error
810 Cooling or frequency setting does not match
8410 Wrong firmware for model

Every WhatsMiner code, with the first check

The MicroBT list in plain words. Codes with a page of their own are linked.

Fans 7 codes
Fans
Code What it means First check
110 Intake fan speed not read Check the fan connector, then the fan, then the power supply.
111 Outlet fan speed not read Check the fan connector, then the fan, then the power supply.
120 Intake fan more than 2,000 rpm off its target Check the fan connector, then the fan, then the power supply.
121 Outlet fan more than 2,000 rpm off its target Check the fan connector, then the fan, then the power supply.
130 Intake fan more than 3,000 rpm off its target Check the fan connector, then the fan, then the power supply.
131 Outlet fan more than 3,000 rpm off its target Check the fan connector, then the fan, then the power supply.
140 Fan speed too high Check the room temperature.
Power supply 40 codes
Power supply
Code What it means First check
200 No power supply found Check the power supply’s flat cable, update the firmware, or replace the power supply.
201 Power supply does not match the settings Check the power supply type; similar models are not interchangeable.
202 Output voltage error Update the firmware or check the power supply.
203 Power supply protecting itself Check the room temperature.
204 Power supply current protection Check the room temperature.
205 Power supply current error Check the grid supply to the machine.
206 Input voltage too low Improve the supply so the input voltage is in range.
207 Input current protection Improve the supply so the input voltage is in range.
208–209 Output voltage changes too much Replace the power supply.
210 Power supply reports an error of its own Read the power supply’s own code.
211 Output current too far from its target Replace the power supply.
212 Too little output voltage margin Contact support.
213 Input voltage and current do not match the power Replace the power supply.
214–215 Power supply control error Contact support.
216–217 Power supply does not respond to settings Replace the power supply.
218 Input below 230 V in high-performance mode Raise the input voltage or leave that mode.
219 Input current incorrect Replace the power supply.
233–235 Output over-temperature protection Check the room temperature.
236–238 Output over-current protection Check the room temperature and the copper-bar screws.
239 Output over-voltage protection Check the grid supply to the machine.
240 Output low-voltage protection Check the grid supply to the machine.
241 Output current unbalanced Replace the power supply.
243–245 Input over-temperature protection Check the room temperature.
246–247 Input over-current protection Replace the power supply.
248–249 Input over-voltage protection Check the grid supply to the machine.
250–251 Input under-voltage protection Check the grid supply to the machine.
253–254 Power supply fan error Replace the power supply.
255–256 Output power protection Check the room temperature.
257 Input over-current on the primary side Switch off and on again; replace the power supply if it returns.
258–259 Three-phase input unbalanced Check the grid supply to the machine.
263–264 Power supply communication lost Check that the control board screws are tight.
267 Power supply watchdog protection Contact support.
268 Output over-current protection Check the room temperature and the copper-bar screws.
269 Input over-current protection Improve the supply so the input voltage is in range.
270 Input over-voltage protection Check the grid supply to the machine.
271 Input under-voltage protection Check the grid supply to the machine.
272–273 Power too high (warning) Check the room temperature.
274 Power supply fan warning Check whether the power supply fan is blocked.
275 Power supply temperature warning Check the room temperature.
280–299 Power supply register error Contact support.
Temperature sensors 8 codes
Temperature sensors
Code What it means First check
300–302 Temperature sensor of a hashboard not found Check the hashboard wiring.
309 No temperature sensor found at all Check the hashboard wiring.
320–322 Temperature reading error on a hashboard Check the control board screws, the adapter board and the flat cable.
326 Coolant temperature sensor not answering Replace the power supply.
329 Control board temperature sensor not answering Replace the power supply.
350–352 Hashboard temperature protection Check the room temperature.
360 Hashboard overheating Check the room temperature.
370 Room temperature swings too much Check the room temperature and the wind at the intake.
Hashboards and chips 21 codes
Hashboards and chips
Code What it means First check
410–412 Hashboard memory (EEPROM) not found Check the adapter board and the flat cable.
420–442 Hashboard memory holds data the firmware cannot use Update to the latest firmware.
450–452 Hashboard memory transfer error Check the adapter board and the flat cable, then update the firmware.
500 No settings for this model in the firmware Update to the latest firmware.
510–512 Hashboard is for another model Fit the correct hashboard.
520–522 Hashboards with different chip types Fit the correct hashboard.
530–532 Hashboard not found Check the adapter board and flat cable, then the control board.
540–542 Chip ID not read With the power off, reseat the adapter board or swap the board positions.
550–552 Bad chips on a hashboard Contact support.
560–562 Hashboard out of balance With the power off, reseat the adapter board or swap the board positions.
570–572 Chip transfer error Contact support.
580–582 Hashboard reset error Ask support if the hashrate is not normal.
590–592 Hashboard frequency too low Contact support.
5010–5012 Chip voltage too low Contact support.
5020–5022 Chip voltage changing Replace the power supply.
5030–5042 Chip temperatures too far apart Check the cooling of the machine.
5050–5052 Chip temperature protection Check the room temperature.
5070–5072 Coolant flow abnormal on a hashboard Check that water flows normally.
5079 Coolant flow too slow Check the flow rate.
5080–5090 Chip temperature calibration failed Restore factory settings and calibrate again.
5110–5112 Frequency ramp-up timed out Restart, tighten the copper-bar screws, or update the firmware.
Room and coolant 4 codes
Room and coolant
Code What it means First check
600 Room too hot Keep the room below 35 °C in normal mode.
610 Room too hot for high-performance mode Keep the room below 30 °C in high-performance mode.
620 Coolant temperature protection Check the coolant temperature.
652 Coolant temperature swings too much Check the coolant temperature.
Control board 5 codes
Control board
Code What it means First check
701 Control board does not support the chips Install the firmware made for this type.
702 Control board version unknown Contact support.
710–712 Control board restarted by itself Update the firmware, check the control board screws, then replace the board.
714 Network connection unstable Check the network cable or replace the control board.
720–722 Serial link to a hashboard failed Update the firmware or replace the control board.
Firmware and settings 9 codes
Firmware and settings
Code What it means First check
800–802 Firmware file failed its check Install the official firmware again.
810 Cooling or frequency change does not match the hashboard Install the immersion firmware again or set the frequency again.
820 Cooling or frequency change does not match the power supply Install the immersion firmware again or set the frequency again.
901 Power rating error Check whether the machine has been modified.
8000 WhatsMinerTool too old Install the latest WhatsMinerTool.
8010–8020 Frequency or hashrate below standard Update the firmware or restore factory settings.
8400 Firmware too old or not official Install the correct official firmware.
8410 Firmware for another WhatsMiner generation Install the correct firmware.
8700 Machine and power supply do not match Fit the correct power supply.
Pools and hashrate 8 codes
Pools and hashrate
Code What it means First check
2000 No pool set Check the pool settings.
2010 All pools disabled Check the network and the pool settings.
2020–2022 Connection to the first, second or third pool failed Check the network and the pool settings.
2030 High share of rejected work Check the network, the pool settings and the coin you mine.
2040 Pool does not support the ASICBoost mode Check the pool settings.
2050 Switch to a new pool failed Check the network and the pool settings.
2310–2320 Hashrate too low Check the grid supply, the network and the room temperature.
2340–2350 Hashrate loss too high Check the grid supply, the network and the room temperature.

Where a WhatsMiner shows its code

WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.

What to check first

Most WhatsMiner faults come from heat, power, fans or the network rather than the chips. Check intake air, input voltage, fan speeds and the pool settings first, and keep the MicroBT stock firmware while you test, so a warranty claim stays open.

WhatsMiner error codes: common questions

How do I clear a WhatsMiner error code?

Fix the cause, then restart the miner once: the code goes when the fault does. Write down the code, the board number and what the miner was doing before you restart, as the log may start again.

Is it safe to keep mining with an error showing?

A network or pool message is harmless and the miner picks up again by itself. With a temperature, fan or power message, switch off first and look for the cause.

What should I send with a warranty claim to MicroBT?

The serial number, the code, a photo or copy of the log, the firmware version and what you have tried. A claim with all five usually needs no second round.

Can you repair or replace the part for me?

Yes. Send us the model and the code. We tell you whether a spare part, a repair or a claim with MicroBT is the quickest way back to mining.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.