WhatsMiner error 206 Low input voltage
The input voltage is too low for the power supply, so the miner slows or stops.
How to fix it
Before you start. Have the input voltage measured at the socket while the miner runs. Never open a power supply: its capacitors hold a dangerous charge after it is switched off.
Confirm the outlet is a 240 V type rated for the miner.
Move other heavy loads off the circuit.
Have an electrician log outlet voltage at boot and under load and fix loose or damaged receptacles.
Power-cycle at the wall for 60 seconds.
If the circuit tests good and the error stays, have the PSU checked.
Likely causes
- 120 V outlet
- Heavy loads on the same circuit
- Undersized or loose wiring
- Ageing PSU
When to stop
Stop if the supply faults on a circuit that measures in spec under load, or if it smells burnt or clicks. Replace the power supply or claim it under warranty.
Contact supportRead it, fix it, claim it
Where to read the code
WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.
How to know it is fixed
Let it run at full load for an hour and look for the code again. Have the voltage at the socket measured while it runs: a supply that is in range with the machine off can still drop under load.
When to claim warranty
Usually not a warranty fault: it points at the site supply. Claim only if the error persists on a verified correct supply; damage caused by wrong input voltage or surges is excluded by most makers.
Warranty and claimsQuestions about WhatsMiner error 206
Is WhatsMiner error 206 the power supply or my wiring?
Try the machine on a circuit that is known to be good, or a machine that works on this circuit. If the fault stays with the circuit, call an electrician. If it follows the machine, look at the supply.
Can I fit any power supply with enough watts?
No. The output voltage, the connectors and the data link have to match the model. Our power supply pages list the miners each one fits.