WhatsMiner error 205 Power current error

The power supply reports a current outside its expected range. MicroBT’s first check is the grid supply to the machine.

How to fix it

Before you start. Have the input voltage measured at the socket while the miner runs. Never open a power supply: its capacitors hold a dangerous charge after it is switched off.

  1. Have the grid supply to the machine checked: voltage, circuit and shared loads.

  2. Power-cycle at the wall.

  3. With power off, check the PSU bus-bar bolts are tight and clean.

  4. Reseat the PSU-to-control-board harness.

  5. Check intake temperature and wall voltage.

  6. If it persists, send the PSU or board for diagnosis.

Likely causes

  1. Loose bus-bar bolts
  2. Hashboard short
  3. PSU current-sensor drift

When to stop

Stop if the supply faults on a circuit that measures in spec under load, or if it smells burnt or clicks. Replace the power supply or claim it under warranty.

Contact support

Read it, fix it, claim it

Where to read the code

WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.

How to know it is fixed

Let it run at full load for an hour and look for the code again. Have the voltage at the socket measured while it runs: a supply that is in range with the machine off can still drop under load.

When to claim warranty

If the error stays with a correct, stable supply and stock settings, it points at the PSU or a hashboard: claim under warranty while in term. Damage from wrong voltage, surges or unstable power is excluded by most makers, so keep your voltage readings and logs as evidence.

Warranty and claims

Questions about WhatsMiner error 205

Is WhatsMiner error 205 the power supply or my wiring?

Try the machine on a circuit that is known to be good, or a machine that works on this circuit. If the fault stays with the circuit, call an electrician. If it follows the machine, look at the supply.

Can I fit any power supply with enough watts?

No. The output voltage, the connectors and the data link have to match the model. Our power supply pages list the miners each one fits.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.