WhatsMiner error 240 PSU output under-voltage protection

Shown as "Low Voltage Protection for Power Output". The power supply’s output voltage fell too low and it protected itself. MicroBT’s first check is the grid supply.

How to fix it

Before you start. Have the input voltage measured at the socket while the miner runs. Never open a power supply: its capacitors hold a dangerous charge after it is switched off.

  1. Have the grid supply to the machine checked: voltage, circuit and shared loads.

  2. Confirm the code via the status page or API.

  3. Power-cycle at the wall breaker.

  4. Lower the power mode one step.

  5. Confirm the PSU model matches the chassis.

  6. With power off, check bolts and harness.

  7. Improve cooling; if it returns under load, send the PSU for repair.

Likely causes

  1. Aged PSU capacitors
  2. PSU under-rated for the chassis
  3. Loose copper-bar bolts
  4. Damaged harness
  5. High room temperature
  6. Recent tune increase

When to stop

Stop if the supply faults on a circuit that measures in spec under load, or if it smells burnt or clicks. Replace the power supply or claim it under warranty.

Contact support

Read it, fix it, claim it

Where to read the code

WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.

How to know it is fixed

Let it run at full load for an hour and look for the code again. Have the voltage at the socket measured while it runs: a supply that is in range with the machine off can still drop under load.

When to claim warranty

If the error stays with a correct, stable supply and stock settings, it points at the PSU or a hashboard: claim under warranty while in term. Damage from wrong voltage, surges or unstable power is excluded by most makers, so keep your voltage readings and logs as evidence.

Warranty and claims

Questions about WhatsMiner error 240

Is WhatsMiner error 240 the power supply or my wiring?

Try the machine on a circuit that is known to be good, or a machine that works on this circuit. If the fault stays with the circuit, call an electrician. If it follows the machine, look at the supply.

Can I fit any power supply with enough watts?

No. The output voltage, the connectors and the data link have to match the model. Our power supply pages list the miners each one fits.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.