WhatsMiner error 200 Power probing error, no power found

During boot the miner switches the PSU on but never sees power reach the hashboards, so it stops before hashing. Dashboards may read "power probing error".

How to fix it

Before you start. Have the input voltage measured at the socket while the miner runs. Never open a power supply: its capacitors hold a dangerous charge after it is switched off.

  1. Unplug the AC cord for 60 seconds and reboot.

  2. Check the outlet, plug and breaker for heat damage.

  3. With power off, reseat the PSU-to-control-board harness and DC connectors.

  4. Try a known-good PSU of the same family.

  5. If the breaker trips or you see burn marks, stop and send for repair.

Likely causes

  1. Faulty PSU
  2. Loose or damaged PSU signal harness
  3. Poor AC or DC connections
  4. Shorted hashboard

When to stop

Stop if the supply faults on a circuit that measures in spec under load, or if it smells burnt or clicks. Replace the power supply or claim it under warranty.

Contact support

Read it, fix it, claim it

Where to read the code

WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.

How to know it is fixed

Let it run at full load for an hour and look for the code again. Have the voltage at the socket measured while it runs: a supply that is in range with the machine off can still drop under load.

When to claim warranty

If the error stays with a correct, stable supply and stock settings, it points at the PSU or a hashboard: claim under warranty while in term. Damage from wrong voltage, surges or unstable power is excluded by most makers, so keep your voltage readings and logs as evidence.

Warranty and claims

Questions about WhatsMiner error 200

Is WhatsMiner error 200 the power supply or my wiring?

Try the machine on a circuit that is known to be good, or a machine that works on this circuit. If the fault stays with the circuit, call an electrician. If it follows the machine, look at the supply.

Can I fit any power supply with enough watts?

No. The output voltage, the connectors and the data link have to match the model. Our power supply pages list the miners each one fits.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.