WhatsMiner error 5070-5072 Water velocity abnormal (hydro)

The coolant flow on one of the three hashboards is not normal, so the firmware slows or stops that board.

Seen on
Hydro models

How to fix it

Before you start. Note the intake air temperature and the chip and board readings on the status page before you change anything. Overheating is almost always about the room or the airflow, so fix those first and leave the machine’s settings for last.

  1. Check that the coolant is flowing normally: pump, valves, filter and hoses.

  2. Confirm the code in the logs.

  3. Power-cycle at the breaker for 60 seconds.

  4. Check coolant level, flow direction and seals.

  5. Bleed air and clean the strainer.

  6. Update or roll back firmware.

  7. Swap the board to see whether the fault follows it.

Likely causes

  1. Air trapped in the cold plate
  2. Blocked strainer or weak pump
  3. Faulty flow sensor or quick-connector seal
  4. Low inlet pressure

When to stop

Stop if one board keeps running far hotter than the others with clean fans and cool intake air, or if you see scorching on the board. That points at the board itself, and opening it can void the warranty.

Contact support

Read it, fix it, claim it

Where to read the code

WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.

How to know it is fixed

Run at full load for an hour and watch the intake, board and chip readings. They should settle and stay level, not creep up. Look again in the hottest part of the day.

When to claim warranty

Claim if flow, pressure and coolant are verified in spec and the code persists. Hydro units run with out-of-spec water may be excluded.

Warranty and claims

Questions about WhatsMiner error 5070-5072

Can I keep mining with WhatsMiner error 5070-5072?

Not for long. A miner that is too hot slows down or stops itself to protect its chips, so it earns less than it should until the heat is gone. Raising a temperature limit hides the warning and leaves the heat.

Is it the room or the machine?

Compare the boards. If all of them read high, look at the room, the dust and the airflow. If one reads far above the rest with the same air, look at that board or its sensor.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.