WhatsMiner error 110 Intake fan speed signal error

Shown as "Fanin detect speed error". The miner reads no speed from the intake fan.

Also shows as
111 · 120

How to fix it

Before you start. Switch the miner off at the breaker and wait until the fans have stopped before you touch them. Use the same fan model and connector the maker fitted; a different fan can read the wrong speed and trigger the error again.

  1. Check the intake fan’s connector, then try another fan or power supply of the correct type.

  2. Power off at the PDU for 60 seconds and restart.

  3. Clear the intake and check room temperature.

  4. If it began after an update, reflash official firmware for the model.

  5. With power off, check the fan spins freely and clean it.

  6. Reseat the fan connector.

  7. Swap fans to see whether the fault follows the fan; replace the faulty fan with an original-spec part.

Likely causes

  1. Dust or worn bearings
  2. Loose or broken fan connector or harness
  3. Blocked intake
  4. High room temperature
  5. Firmware issue after an update
  6. Failed fan supply on the control board

When to stop

Stop if a new, correct fan still reports the fault on the same port. The fan header or the control board is then the likely cause, and that is a repair or warranty job.

Contact support

Read it, fix it, claim it

Where to read the code

WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.

How to know it is fixed

All fans should report speeds close to each other and hold them. Listen for one that rises and falls, and look in the log an hour later for a new fan line.

When to claim warranty

Fans are wear parts. If an original-spec replacement fan and harness do not clear it, the control board is the likely fault: claim while in term.

Warranty and claims

Questions about WhatsMiner error 110

Can I run the miner with the fan that shows WhatsMiner error 110?

No. Without its full airflow the chips overheat, and most air-cooled miners stop hashing when a fan is missing or too slow. Replace the fan rather than working around the check.

Which fan do I need?

One with the same size, voltage, connector and speed as the original. Our fan pages list the figures and the models each one fits.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.