WhatsMiner error 600 Environment temperature too high
The room is too hot. MicroBT asks for a room below 35 °C in normal mode.
How to fix it
Before you start. Note the intake air temperature and the chip and board readings on the status page before you change anything. Overheating is almost always about the room or the airflow, so fix those first and leave the machine’s settings for last.
Power off for 60 seconds and restart.
Compare the reading with a handheld thermometer at the intake.
With power off, vacuum the grille and fins.
Check clearances and room temperature.
Check all fans run at similar speeds.
Reflash verified official firmware over a wired connection.
Likely causes
- Dusty intake
- Blocked airflow
- Hot room
- Slow or stalled fan
- Corroded sensor connector
- Low line voltage
When to stop
Stop if one board keeps running far hotter than the others with clean fans and cool intake air, or if you see scorching on the board. That points at the board itself, and opening it can void the warranty.
Contact supportRead it, fix it, claim it
Where to read the code
WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.
How to know it is fixed
Run at full load for an hour and watch the intake, board and chip readings. They should settle and stay level, not creep up. Look again in the hottest part of the day.
When to claim warranty
Overheating caused by room air, dust or blocked airflow is not a defect. Claim if the same board or sensor still faults with intake air in spec, clean working fans and stock settings.
Warranty and claimsQuestions about WhatsMiner error 600
Can I keep mining with WhatsMiner error 600?
Not for long. A miner that is too hot slows down or stops itself to protect its chips, so it earns less than it should until the heat is gone. Raising a temperature limit hides the warning and leaves the heat.
Is it the room or the machine?
Compare the boards. If all of them read high, look at the room, the dust and the airflow. If one reads far above the rest with the same air, look at that board or its sensor.