WhatsMiner error 350-352 Hashboard high-temperature protection

Per-board high-temperature protection on board 0, 1 or 2: the firmware lowers that board's frequency and voltage to cool it. Expect about 78 to 84 C on the flagged board against 65 to 72 C on the others.

How to fix it

Before you start. Note the intake air temperature and the chip and board readings on the status page before you change anything. Overheating is almost always about the room or the airflow, so fix those first and leave the machine’s settings for last.

  1. Hard power-cycle at the PDU for 60 seconds.

  2. Keep intake air at or below 30 C.

  3. Clear space at the intake and, with power off, clean mesh and fins.

  4. Check fan speeds and replace weak fans as a set.

  5. Swap the flagged board to another slot.

  6. If it stays hot with good airflow, send the board for repair.

Likely causes

  1. Dusty fins or intake mesh
  2. Blocked airflow
  3. Aged thermal paste
  4. Weak fans
  5. Loose board connectors
  6. Hot room

When to stop

Stop if one board keeps running far hotter than the others with clean fans and cool intake air, or if you see scorching on the board. That points at the board itself, and opening it can void the warranty.

Contact support

Read it, fix it, claim it

Where to read the code

WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.

How to know it is fixed

Run at full load for an hour and watch the intake, board and chip readings. They should settle and stay level, not creep up. Look again in the hottest part of the day.

When to claim warranty

Overheating caused by room air, dust or blocked airflow is not a defect. Claim if the same board or sensor still faults with intake air in spec, clean working fans and stock settings.

Warranty and claims

Questions about WhatsMiner error 350-352

Can I keep mining with WhatsMiner error 350-352?

Not for long. A miner that is too hot slows down or stops itself to protect its chips, so it earns less than it should until the heat is gone. Raising a temperature limit hides the warning and leaves the heat.

Is it the room or the machine?

Compare the boards. If all of them read high, look at the room, the dust and the airflow. If one reads far above the rest with the same air, look at that board or its sensor.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.