WhatsMiner error 275 PSU over-temperature warning

A warning that the power supply is getting too hot. MicroBT’s first check is the room temperature.

How to fix it

Before you start. Have the input voltage measured at the socket while the miner runs. Never open a power supply: its capacitors hold a dangerous charge after it is switched off.

  1. Confirm 275 is the only code.

  2. Keep intake air at or below 30 C.

  3. Clean or replace the PSU filter.

  4. Check the PSU fan speeds up.

  5. Keep about 30 cm clear behind the unit.

  6. Lower the tune one step if it persists.

Likely causes

  1. Hot intake air
  2. Clogged PSU filter
  3. Weak PSU fan
  4. Dried thermal compound
  5. Aggressive tune

When to stop

Stop if the supply faults on a circuit that measures in spec under load, or if it smells burnt or clicks. Replace the power supply or claim it under warranty.

Contact support

Read it, fix it, claim it

Where to read the code

WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.

How to know it is fixed

Let it run at full load for an hour and look for the code again. Have the voltage at the socket measured while it runs: a supply that is in range with the machine off can still drop under load.

When to claim warranty

Overheating caused by room air, dust or blocked airflow is not a defect. Claim if the same board or sensor still faults with intake air in spec, clean working fans and stock settings.

Warranty and claims

Questions about WhatsMiner error 275

Is WhatsMiner error 275 the power supply or my wiring?

Try the machine on a circuit that is known to be good, or a machine that works on this circuit. If the fault stays with the circuit, call an electrician. If it follows the machine, look at the supply.

Can I fit any power supply with enough watts?

No. The output voltage, the connectors and the data link have to match the model. Our power supply pages list the miners each one fits.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.