Avalon error codes

Every Avalon code we cover, grouped by fault, with causes and fixes.

Avalon codes by fault

Avalon error codes
Code What it means
Overheating
PVT_T above 85 C Chip temperature in shutdown range
Fans
PS bit 2048 (FAN_error) PSU status flag FAN_error
Hashboards
ASICCRC ASIC CRC error
E: no asics!! No ASICs found
PVT_V drift beyond 40 mV Domain voltage drift
SYSTEMSTATU[0] Work < 3 Hashboard enumeration incomplete
Power supply
PS bit 1 (Input_UV) PSU status flag input under-voltage
PS[0..2] = 0 PSU telemetry reads zero
Control board
BOOTBY Reboot cause code

Where a Avalon shows its code

Open the miner’s IP address in a browser and read its status and log there. If you do not know the address, Canaan’s FMS program scans a range of addresses and opens the page of any machine it finds.

What to check first

Most Avalon faults come from heat, power, fans or the network rather than the chips. Check intake air, input voltage, fan speeds and the pool settings first, and keep the Canaan stock firmware while you test, so a warranty claim stays open.

Avalon error codes: common questions

How do I clear a Avalon error code?

Fix the cause, then restart the miner once: the code goes when the fault does. Write down the code, the board number and what the miner was doing before you restart, as the log may start again.

Is it safe to keep mining with an error showing?

A network or pool message is harmless and the miner picks up again by itself. With a temperature, fan or power message, switch off first and look for the cause.

What should I send with a warranty claim to Canaan?

The serial number, the code, a photo or copy of the log, the firmware version and what you have tried. A claim with all five usually needs no second round.

Can you repair or replace the part for me?

Yes. Send us the model and the code. We tell you whether a spare part, a repair or a claim with Canaan is the quickest way back to mining.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.