Avalon BOOTBY Reboot cause code

After every restart, the MM firmware on Avalon miners writes BOOTBY[0xNN] to the log. The value in brackets records why the miner restarted: a cold start after a power cut, overheating, a network problem, a watchdog, too little hashrate, or a restart you asked for.

Seen on
Avalon A11xx to A15xx (MM firmware)

Every value of this code

The number in brackets tells you why the miner restarted.

Every value of this code
Value What it means Fault
BOOTBY[0x01] Hard reboot / cold startReboot cause written by the MM firmware: hard reboot or unknown cold start, such as a power event, first boot after flashing or dirty mains. Power supply
BOOTBY[0x02] Overheat rebootReboot caused by overheating, usually with chip temperature (PVT_T) above 85 C. It is sometimes shown as 0A1E. Overheating
BOOTBY[0x03] Network problem rebootReboot caused by a network problem such as a stratum drop, DNS timeout or bad pool response. Network and pool
BOOTBY[0x04] Network back-end restartThe MM firmware restarted its network services (stratum, API or web). Control board
BOOTBY[0x05] API-triggered rebootReboot requested through the API by an operator, controller or script. Usually healthy. Firmware
BOOTBY[0x10] Watchdog reboot (unclassified)The MM watchdog fired without a classified cause. There is no published meaning for this reboot code, so treat it as a general fault. Control board
BOOTBY[0x11] No hashrate after bootNo hashrate was detected within 5 minutes of boot. Hashboards
BOOTBY[0x12] Hashrate below 70 percentHashrate stayed below 70 percent of nameplate. Hashboards
BOOTBY[0x21] Soft reboot after configuration changeIntentional soft reboot after a configuration change. Normal. Firmware

How to fix it

Before you start. Back up your pool settings, then try a full power cycle before anything else. Use only firmware from the maker’s own website, matched to your exact model.

  1. Open the miner log and note the BOOTBY value and how often it appears; one restart after a power event or a settings change is normal.

  2. Look up the value in the table on this page to see which part of the machine it points at.

  3. For 0x01, have the input voltage checked under load and use a dedicated 220 to 240 V circuit.

  4. For 0x02, clean the intake filter, clear the front of the unit and measure the intake air.

  5. For 0x03 and 0x04, test a known-good DNS server and a second pool for 30 minutes, then reseat the controller USB cable and ribbons with the power off.

  6. For 0x11 and 0x12, swap hashboards between slots to see whether the fault follows the board or stays with the slot.

  7. For 0x05 repeating every few seconds, check your monitoring or fleet software for a reboot loop.

Likely causes

  1. A power cut or poor mains quality (0x01)
  2. Overheating from hot intake air or a dirty filter (0x02)
  3. A pool, DNS or network drop (0x03, 0x04)
  4. A hashboard that produced no or too little hashrate (0x11, 0x12)
  5. A watchdog reset with no recorded cause (0x10)
  6. A restart requested by you, your software or a settings change (0x05, 0x21)

When to stop

Stop if the board will not boot after a reset and a clean firmware flash. A control board that will not start needs replacing; a hosted machine is swapped by our technicians.

Contact support

Read it, fix it, claim it

Where to read the code

Open the miner’s IP address in a browser and read its status and log there. If you do not know the address, Canaan’s FMS program scans a range of addresses and opens the page of any machine it finds.

How to know it is fixed

Your pool settings, the clock and the hashrate should be back. Restart once more from the web page to see that the board starts by itself.

When to claim warranty

Restarts caused by the site supply, room air, the network or your own commands are not defects. Claim when a value that points at the hardware (0x04, 0x10, 0x11 or 0x12) keeps coming back on a correct supply, cool intake air and stock settings, and open the ticket before you open the case.

Warranty and claims

Models this code affects

Setup guides for the Avalon models that show this code.

Questions about Avalon “BOOTBY”

Does Avalon “BOOTBY” mean a new control board?

Not at first. Power, cables and firmware cause many of these messages and are cheaper to rule out. Replace the board when it still fails after a reset and the maker’s own firmware.

Do I lose my settings when I change the control board?

Yes. Pool addresses, worker names and network settings live on the board, so copy them before you start.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.