Avalon PS[0..2] = 0 PSU telemetry reads zero

All PSU telemetry fields reading 0 means the PSU telemetry channel has dropped.

Seen on
Avalon A11xx to A15xx (MM firmware)

How to fix it

Before you start. Have the input voltage measured at the socket while the miner runs. Never open a power supply: its capacitors hold a dangerous charge after it is switched off.

  1. Power off at the breaker for 60 seconds and restart.

  2. With power off, reseat the PSU communication cable.

  3. Try a known-good PSU of the same model.

  4. If it persists, send for repair.

Likely causes

  1. PSU communication cable fault
  2. PSU fault
  3. Controller fault

When to stop

Stop if the supply faults on a circuit that measures in spec under load, or if it smells burnt or clicks. Replace the power supply or claim it under warranty.

Contact support

Read it, fix it, claim it

Where to read the code

Open the miner’s IP address in a browser and read its status and log there. If you do not know the address, Canaan’s FMS program scans a range of addresses and opens the page of any machine it finds.

How to know it is fixed

Let it run at full load for an hour and look for the code again. Have the voltage at the socket measured while it runs: a supply that is in range with the machine off can still drop under load.

When to claim warranty

Canaan gives no warranty on PSUs, though a defective PSU can be reported within 3 days of delivery. Claim the miner only if a known-good PSU does not clear it.

Warranty and claims

Models this code affects

Setup guides for the Avalon models that show this code.

Questions about Avalon “PS[0..2] = 0”

Is Avalon “PS[0..2] = 0” the power supply or my wiring?

Try the machine on a circuit that is known to be good, or a machine that works on this circuit. If the fault stays with the circuit, call an electrician. If it follows the machine, look at the supply.

Can I fit any power supply with enough watts?

No. The output voltage, the connectors and the data link have to match the model. Our power supply pages list the miners each one fits.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.