Avalon PS bit 1 (Input_UV) PSU status flag input under-voltage
In the PS error bitmap of the MM log, value 1 is the Input_UV (input under-voltage) flag.
- Also shows as
- PS error bitmap
- Seen on
- Avalon A11xx to A15xx (MM firmware)
How to fix it
Before you start. Have the input voltage measured at the socket while the miner runs. Never open a power supply: its capacitors hold a dangerous charge after it is switched off.
Have the supply voltage checked under load by a qualified person.
Move the miner to a dedicated circuit.
Restart and check whether the flag clears.
Likely causes
- Low or sagging mains voltage
- Overloaded circuit
When to stop
Stop if the supply faults on a circuit that measures in spec under load, or if it smells burnt or clicks. Replace the power supply or claim it under warranty.
Contact supportRead it, fix it, claim it
Where to read the code
Open the miner’s IP address in a browser and read its status and log there. If you do not know the address, Canaan’s FMS program scans a range of addresses and opens the page of any machine it finds.
How to know it is fixed
Let it run at full load for an hour and look for the code again. Have the voltage at the socket measured while it runs: a supply that is in range with the machine off can still drop under load.
When to claim warranty
Usually not a warranty fault: it points at the site supply. Claim only if the error persists on a verified correct supply; damage caused by wrong input voltage or surges is excluded by most makers. Canaan gives no warranty on PSUs.
Warranty and claimsModels this code affects
Setup guides for the Avalon models that show this code.
Questions about Avalon “PS bit 1 (Input_UV)”
Is Avalon “PS bit 1 (Input_UV)” the power supply or my wiring?
Try the machine on a circuit that is known to be good, or a machine that works on this circuit. If the fault stays with the circuit, call an electrician. If it follows the machine, look at the supply.
Can I fit any power supply with enough watts?
No. The output voltage, the connectors and the data link have to match the model. Our power supply pages list the miners each one fits.