WhatsMiner error 264 PSU communication error

Shown as "power communication error". The control board has lost contact with the power supply. MicroBT’s first check is whether the control board’s screws are tight.

Also shows as
263

How to fix it

Before you start. Have the input voltage measured at the socket while the miner runs. Never open a power supply: its capacitors hold a dangerous charge after it is switched off.

  1. With the machine off and unplugged, check that the control board’s screws are tight.

  2. Unplug at the wall for 60 seconds and reboot.

  3. With power off, reseat the PSU signal cable.

  4. Swap a known-good cable, then PSU, then control board.

  5. If 264 comes with falling hashrate, send for repair.

Likely causes

  1. Loose or damaged PSU signal cable
  2. Failing PSU telemetry circuit
  3. Faulty control board

When to stop

Stop if the supply faults on a circuit that measures in spec under load, or if it smells burnt or clicks. Replace the power supply or claim it under warranty.

Contact support

Read it, fix it, claim it

Where to read the code

WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.

How to know it is fixed

Let it run at full load for an hour and look for the code again. Have the voltage at the socket measured while it runs: a supply that is in range with the machine off can still drop under load.

When to claim warranty

Hardware fault. If the unit is inside the maker's warranty term, open a repair ticket after the outside-the-case checks and before opening the case or replacing parts: opening the unit, mixing boards, non-original parts or non-stock firmware can make the repair chargeable or refused.

Warranty and claims

Questions about WhatsMiner error 264

Is WhatsMiner error 264 the power supply or my wiring?

Try the machine on a circuit that is known to be good, or a machine that works on this circuit. If the fault stays with the circuit, call an electrician. If it follows the machine, look at the supply.

Can I fit any power supply with enough watts?

No. The output voltage, the connectors and the data link have to match the model. Our power supply pages list the miners each one fits.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.