WhatsMiner error 714 Network connection unstable
The network connection of the control board is seriously unstable, so pool connections drop.
How to fix it
Before you start. Check that the miner has a link light and an IP address on your network. Copy your pool address, worker name and password exactly; one wrong character is enough to block the connection.
Cut power at the PDU for about a minute.
Restart the router.
Replace the patch cable.
Try another switch port.
Give the miner a fixed address outside the DHCP range.
Connect directly to the router to isolate the fault.
Install an earlier official firmware.
Likely causes
- Worn patch cable
- Faulty switch port
- Router DHCP problems
- Link negotiation issues
- Failing controller network chip
When to stop
Stop if the miner shows the fault on a known good cable and network with settings that work on another machine. Send us the log lines and we will help you trace it.
Contact supportRead it, fix it, claim it
Where to read the code
WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.
How to know it is fixed
The pool’s own page is the proof: the worker appears online within a few minutes and shows accepted shares.
When to claim warranty
Not a warranty matter in most cases: it is a network or pool setting. Claim only if a hardware fault such as a dead Ethernet port is confirmed on a known-good network.
Warranty and claimsQuestions about WhatsMiner error 714
Is WhatsMiner error 714 a fault of the miner?
Usually not. The address, the worker name, the cable or the router is the more common cause. Test the same settings on another machine before you suspect the hardware.
Should I set a second pool?
Yes. Miners accept more than one pool address and move to the next when the first does not answer, so an outage at one pool does not stop the machine.