WhatsMiner error 2010 All pools disabled

Logged as "all pools disabled". No pool is active, so the miner submits no work.

How to fix it

Before you start. Check that the miner has a link light and an IP address on your network. Copy your pool address, worker name and password exactly; one wrong character is enough to block the connection.

  1. Confirm the 2010 line in the log.

  2. Check all three pool slots are filled correctly.

  3. Test the pool host and port from your network.

  4. Check the worker on the pool's dashboard.

  5. Confirm the miner clock is within 60 seconds of UTC.

  6. Factory reset and set up one known-good pool.

Likely causes

  1. Wrong or empty pool settings
  2. Blocked stratum port
  3. Invalid worker credentials
  4. Clock out of sync
  5. Firmware fault after reset

When to stop

Stop if the miner shows the fault on a known good cable and network with settings that work on another machine. Send us the log lines and we will help you trace it.

Contact support

Read it, fix it, claim it

Where to read the code

WhatsMinerTool, MicroBT’s own program, finds the machines on your network and shows the code of each one. Write the code down before you restart: the last digit of a board code names the hashboard, so 350, 351 and 352 are three different boards.

How to know it is fixed

The pool’s own page is the proof: the worker appears online within a few minutes and shows accepted shares.

When to claim warranty

Not a warranty matter in most cases: it is a network or pool setting. Claim only if a hardware fault such as a dead Ethernet port is confirmed on a known-good network.

Warranty and claims

Questions about WhatsMiner error 2010

Is WhatsMiner error 2010 a fault of the miner?

Usually not. The address, the worker name, the cable or the router is the more common cause. Test the same settings on another machine before you suspect the hardware.

Should I set a second pool?

Yes. Miners accept more than one pool address and move to the next when the first does not answer, so an outage at one pool does not stop the machine.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.