IceRiver error 801 Corrupt or mismatched firmware image

The firmware image is corrupt or does not match the model.

Also shows as
800 · 802
Seen on
KS series

How to fix it

Before you start. Download firmware only from the maker’s own site, for your exact model and cooling type. Keep the power steady during an update; a cut in the middle can leave the control board unable to boot.

  1. Stop retrying and wait a couple of minutes.

  2. Power-cycle at the breaker for 30 seconds.

  3. Download the firmware again from IceRiver's official portal and confirm file size and model.

  4. Use a wired connection on the same subnet with VPN off.

  5. Try the previous official version.

  6. If recovery fails, use SD-card reflash or contact IceRiver support.

Likely causes

  1. Corrupted download
  2. Wrong model's firmware
  3. Unstable Wi-Fi or VPN
  4. Power dip
  5. Earlier third-party overclocking firmware

When to stop

Stop if the miner will not boot after a clean flash from the maker’s file. Third-party firmware can void the warranty, so ask the maker or us before you try one.

Contact support

Read it, fix it, claim it

Where to read the code

Open the miner’s IP address in a browser on the same network and sign in to its dashboard. The code or message shows on the status page and in the kernel or miner log. Copy it exactly, including any chain or board number, before you restart the machine.

How to know it is fixed

The status page should show the new version number, all hashboards and your pool settings. Update one machine first and let it run for a day before you do the rest.

When to claim warranty

Reflash the maker's official firmware first. If the control board will not accept official firmware or recovery, claim while in term; faults that follow third-party or overclocking firmware can be chargeable or refused.

Warranty and claims

Questions about IceRiver error 801

Can I go back to the old firmware after IceRiver error 801?

Sometimes. Some releases block an older version, so read the release notes before you update. If the miner no longer starts, the maker’s recovery file on an SD card is the usual way back.

Is a factory reset safe?

Yes. It restores the settings and does not touch the hardware. Copy your pool details first, because you will enter them again.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.