IceRiver error 110/111 Fan speed low

One of the two fans has low rpm: 110 the front fan, 111 the rear fan. Hashrate can drop 15 to 40 percent.

Also shows as
120/121
Seen on
KS series

How to fix it

Before you start. Switch the miner off at the breaker and wait until the fans have stopped before you touch them. Use the same fan model and connector the maker fitted; a different fan can read the wrong speed and trigger the error again.

  1. Power off for 60 seconds and restart.

  2. Clear airflow paths and check room temperature.

  3. If it began after an update, return to official firmware.

  4. With power off, clean the fans, check bearings and reseat connectors.

  5. Swap fans between headers to isolate the fault.

  6. Replace the failed fan with the original type.

Likely causes

  1. Blocked airflow
  2. Dust
  3. Worn bearings
  4. Loose connectors
  5. Dead fan
  6. Fan supply fault
  7. Bad firmware update

When to stop

Stop if a new, correct fan still reports the fault on the same port. The fan header or the control board is then the likely cause, and that is a repair or warranty job.

Contact support

Read it, fix it, claim it

Where to read the code

Open the miner’s IP address in a browser on the same network and sign in to its dashboard. The code or message shows on the status page and in the kernel or miner log. Copy it exactly, including any chain or board number, before you restart the machine.

How to know it is fixed

All fans should report speeds close to each other and hold them. Listen for one that rises and falls, and look in the log an hour later for a new fan line.

When to claim warranty

Fans are wear parts. If an original-spec replacement fan and harness do not clear it, the control board is the likely fault: claim while in term.

Warranty and claims

Questions about IceRiver error 110/111

Can I run the miner with the fan that shows IceRiver error 110/111?

No. Without its full airflow the chips overheat, and most air-cooled miners stop hashing when a fan is missing or too slow. Replace the fan rather than working around the check.

Which fan do I need?

One with the same size, voltage, connector and speed as the original. Our fan pages list the figures and the models each one fits.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.