IceRiver error 233-239 Over-temperature warnings

Over-temperature warnings, not hard shutdowns: 233 and 234 the PSU, 235 to 237 the hashboard heatsinks, 238 the voltage regulators and 239 the exhaust air. KS5L and KS5M units are the most affected.

Seen on
KS5L, KS5M, KS series

How to fix it

Before you start. Note the intake air temperature and the chip and board readings on the status page before you change anything. Overheating is almost always about the room or the airflow, so fix those first and leave the machine’s settings for last.

  1. Power-cycle at the wall for 60 seconds.

  2. Switch from performance to normal mode.

  3. Lower room temperature.

  4. With power off, clean the intake filter and grilles.

  5. Replace any weak fan.

  6. Have line voltage checked under load.

  7. Roll back firmware if it began after an update.

Likely causes

  1. Hot room
  2. Dirty intake filter or grilles
  3. Weak fan
  4. Loose PSU or board power cables
  5. Low line voltage
  6. Firmware change

When to stop

Stop if one board keeps running far hotter than the others with clean fans and cool intake air, or if you see scorching on the board. That points at the board itself, and opening it can void the warranty.

Contact support

Read it, fix it, claim it

Where to read the code

Open the miner’s IP address in a browser on the same network and sign in to its dashboard. The code or message shows on the status page and in the kernel or miner log. Copy it exactly, including any chain or board number, before you restart the machine.

How to know it is fixed

Run at full load for an hour and watch the intake, board and chip readings. They should settle and stay level, not creep up. Look again in the hottest part of the day.

When to claim warranty

Overheating caused by room air, dust or blocked airflow is not a defect. Claim if the same board or sensor still faults with intake air in spec, clean working fans and stock settings.

Warranty and claims

Models this code affects

Setup guides for the IceRiver models that show this code.

Questions about IceRiver error 233-239

Can I keep mining with IceRiver error 233-239?

Not for long. A miner that is too hot slows down or stops itself to protect its chips, so it earns less than it should until the heat is gone. Raising a temperature limit hides the warning and leaves the heat.

Is it the room or the machine?

Compare the boards. If all of them read high, look at the room, the dust and the airflow. If one reads far above the rest with the same air, look at that board or its sensor.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.