IceRiver error 300 Temperature sensor no reading

A hashboard temperature sensor gives no reading.

Also shows as
301 · 302
Seen on
KS series

How to fix it

Before you start. Power off and unplug the miner before you reseat any cable. Write down which chain number the log names, so you can tell whether the fault follows the board or stays with the slot when you swap cables.

  1. Power off fully and restart.

  2. Confirm the firmware is official for the model.

  3. Factory reset.

  4. Check room temperature and airflow.

  5. With power off, reseat connectors.

  6. Swap the hashboard to another slot.

  7. Reflash official firmware; if the fault follows the board, send it for repair.

Likely causes

  1. Loose ribbon or power connectors
  2. Cracked solder joints
  3. Damaged ribbon wires
  4. Failed sensor chip
  5. Corrosion
  6. Faulty firmware release

When to stop

Stop if the same board fails after you have reseated its cables and checked its power. Chip and board faults need a repair bench; do not open the board yourself if the machine is still under warranty.

Contact support

Read it, fix it, claim it

Where to read the code

Open the miner’s IP address in a browser on the same network and sign in to its dashboard. The code or message shows on the status page and in the kernel or miner log. Copy it exactly, including any chain or board number, before you restart the machine.

How to know it is fixed

Every board should show its full chip count and a similar hashrate, and the average at your pool should return to the rated figure. A board that drops out again within a day has not been fixed by the restart.

When to claim warranty

Hardware fault. If the unit is inside the maker's warranty term, open a repair ticket after the outside-the-case checks and before opening the case or replacing parts: opening the unit, mixing boards, non-original parts or non-stock firmware can make the repair chargeable or refused.

Warranty and claims

Questions about IceRiver error 300

Will the miner still earn with IceRiver error 300?

Often yes, with the boards that still work: a three-board miner that loses one runs at about two thirds of its hashrate. Some models stop altogether. Check what your pool receives.

Can a hashboard be repaired?

Yes, by a repair bench that can test and replace single chips. While the maker’s warranty runs, go to the maker first: an opened board can end the cover.

Still faulting after these steps?

See whether a maker RMA or a local repair costs less.