How to set up the Innosilicon A9++ ZMaster
Power, network and pool steps for the A9++ ZMaster, in order.
What you need
- Power draw
- 1,550 W
- Room temperature
- 5 to 45 °C
- Noise
- 75 dB
- Network
- Ethernet
Setup steps
-
Place it with cool air
Pick a dry, clean spot where hot exhaust cannot loop back to the intake. It runs in 5 to 45 °C. Leave free space at the front and the back, and lead the warm air out of the room. Do not stack machines directly on each other.
-
Wire the power
Use a dedicated circuit sized for the power draw on the rating label.
-
Connect the network
Plug it into your router or switch with a network cable, then find its IP address in the router or the maker's IP tool. A fixed address helps: reserve one for the machine in your router, so the same address opens it after a restart. No port has to be opened to the internet.
-
Point it at a pool
Open its dashboard and enter your Zcash pool address, worker name and password. Most pools write the worker as account.worker; solo pools often take your wallet address instead. Enter a second pool as a backup, change the default password of the dashboard, and save.
-
Check it is hashing
After a few minutes, check that hashrate, temperatures and fan speeds look normal. The pool shows the worker within a few minutes. Judge the hashrate by the pool’s 24-hour average, because the figure over minutes swings with luck. Write down the normal temperatures, so you notice later when they change.
Innosilicon A9++ ZMaster setup questions
How does the Innosilicon A9++ ZMaster connect to the internet?
Through Ethernet. Once it is connected, find its IP address in your router and open that address in a browser on the same network to reach its dashboard.
What room temperature does the Innosilicon A9++ ZMaster need?
The maker rates it for 5 to 45 °C. Keep the hot exhaust away from the intake, because air that loops back raises chip temperatures and can trigger a shutdown.
What hashrate should the Innosilicon A9++ ZMaster show?
About 140 KSol/s as an average over a day, at stock settings. A little above or below is normal; a lasting drop of a tenth or more points at heat, power or one hashboard.
How much heat does the Innosilicon A9++ ZMaster give off?
All the power it draws leaves it as heat: 1,550 W is about 5,300 BTU an hour. Plan the ventilation or cooling of the room for that, all day.
What does the Innosilicon A9++ ZMaster cost to run?
Its 1,550 W use about 1,116 kWh in 30 days. Multiply that by the price per kWh on your power bill: at $0.10 it is about $112, at $0.20 about $223. Hosted with us it is about $83 at $0.074, for 10–49 machines.
What does the Innosilicon A9++ ZMaster mine?
It mines Zcash on the Equihash (200,9) algorithm. Point it at a pool for that coin with your own payout address.