How to set up the Antminer DR3
Power, network and pool steps for the Antminer DR3, in order.
What you need
- Power draw
- 1,410 W
- Room temperature
- 0 to 40 °C
- Noise
- 76 dB
- Power connector
- 10 PCIe power connectors, DC 11.6-13 V from an external PSU (APW3 series, APW5 o
Setup steps
-
Place it with cool air
Pick a dry, clean spot where hot exhaust cannot loop back to the intake. It runs in 0 to 40 °C. Leave free space at the front and the back, and lead the warm air out of the room. Do not stack machines directly on each other.
-
Wire the power
Use a dedicated circuit sized for the power draw on the rating label.
-
Connect the network
Plug it into your router or switch with a network cable, then find its IP address in the router or the maker's IP tool. A fixed address helps: reserve one for the machine in your router, so the same address opens it after a restart. No port has to be opened to the internet.
-
Point it at a pool
Open its dashboard and enter your BLAKE-256 (14 rounds) pool address, worker name and password. Most pools write the worker as account.worker; solo pools often take your wallet address instead. Enter a second pool as a backup, change the default password of the dashboard, and save.
-
Check it is hashing
After a few minutes, check that hashrate, temperatures and fan speeds look normal. The pool shows the worker within a few minutes. Judge the hashrate by the pool’s 24-hour average, because the figure over minutes swings with luck. Write down the normal temperatures, so you notice later when they change.
Antminer DR3 setup questions
What room temperature does the Antminer DR3 need?
The maker rates it for 0 to 40 °C. Keep the hot exhaust away from the intake, because air that loops back raises chip temperatures and can trigger a shutdown.
What hashrate should the Antminer DR3 show?
About 7.8 TH/s as an average over a day, at stock settings. A little above or below is normal; a lasting drop of a tenth or more points at heat, power or one hashboard.
How much heat does the Antminer DR3 give off?
All the power it draws leaves it as heat: 1,410 W is about 4,800 BTU an hour. Plan the ventilation or cooling of the room for that, all day.
What does the Antminer DR3 cost to run?
Its 1,410 W use about 1,015 kWh in 30 days. Multiply that by the price per kWh on your power bill: at $0.10 it is about $102, at $0.20 about $203. Hosted with us it is about $75 at $0.074, for 10–49 machines.
What does the Antminer DR3 mine?
It mines BLAKE-256 (14 rounds). Point it at a BLAKE-256 (14 rounds) mining pool with your own payout address.