How to set up the Antminer S23 Hyd 3U

Power, network and pool steps for the Antminer S23 Hyd 3U, in order.

Bitmain Antminer S23 Hyd 3U

What you need

Input voltage
380–415 V · three-phase
Power draw
11,020 W
Inlet water
20 to 50 °C
Power connector
LP34
Network
RJ45 Ethernet 10/100M
Coolant
Antifreeze / pure water / deionized water

Setup steps

  1. Connect the cooling loop

    Fill the loop with Antifreeze / pure water / deionized water and keep inlet water at 20 to 50 °C before you power on. Check every joint for leaks and bleed the air out of the loop first. The flow has to be steady before the machine gets power, because the chips heat up within seconds.

  2. Wire the power

    It needs 380–415 V · three-phase and draws 11,020 W. Use a dedicated circuit sized for that load.

  3. Connect the network

    Plug it into your router or switch with a network cable, then find its IP address in the router or the maker's IP tool. A fixed address helps: reserve one for the machine in your router, so the same address opens it after a restart. No port has to be opened to the internet.

  4. Point it at a pool

    Open its dashboard and enter your Bitcoin pool address, worker name and password. Most pools write the worker as account.worker; solo pools often take your wallet address instead. Enter a second pool as a backup, change the default password of the dashboard, and save.

  5. Check it is hashing

    After a few minutes, check that hashrate, temperatures and fan speeds look normal. The pool shows the worker within a few minutes. Judge the hashrate by the pool’s 24-hour average, because the figure over minutes swings with luck. Write down the normal temperatures, so you notice later when they change.

Antminer S23 Hyd 3U setup questions

How much power does the Antminer S23 Hyd 3U use?

The Antminer S23 Hyd 3U draws 11,020 W on 380–415 V. Running all day, that is about 264.5 kWh of electricity every 24 hours.

How does the Antminer S23 Hyd 3U connect to the internet?

Through RJ45 Ethernet 10/100M. Once it is connected, find its IP address in your router and open that address in a browser on the same network to reach its dashboard.

What water temperature does the Antminer S23 Hyd 3U need?

The maker rates the inlet water at 20 to 50 °C. Keep the loop within that range before and during mining.

What hashrate should the Antminer S23 Hyd 3U show?

About 1,160 TH/s as an average over a day, at stock settings. A little above or below is normal; a lasting drop of a tenth or more points at heat, power or one hashboard.

How much heat does the Antminer S23 Hyd 3U give off?

All the power it draws leaves it as heat: 11,020 W is about 37,600 BTU an hour. Plan the ventilation or cooling of the room for that, all day.

What does the Antminer S23 Hyd 3U cost to run?

Its 11,020 W use about 7,934 kWh in 30 days. Multiply that by the price per kWh on your power bill: at $0.10 it is about $793, at $0.20 about $1,587. Hosted with us it is about $587 at $0.074, for 10–49 machines.

What does the Antminer S23 Hyd 3U mine?

It mines Bitcoin on the SHA-256 algorithm. Point it at a pool for that coin with your own payout address.

Rather not run it yourself?

Ship it to our US facility. We rack it, power it and keep it running.