How to set up the Antminer T17+
Power, network and pool steps for the Antminer T17+, in order.
What you need
- Power draw
- 3,200 W
- Room temperature
- 0 to 40 °C
- Noise
- 82 dB
- Power connector
- Built-in PSU
Setup steps
-
Place it with cool air
Pick a dry, clean spot where hot exhaust cannot loop back to the intake. It runs in 0 to 40 °C. Leave free space at the front and the back, and lead the warm air out of the room. Do not stack machines directly on each other.
-
Wire the power
Use a dedicated circuit sized for the power draw on the rating label.
-
Connect the network
Plug it into your router or switch with a network cable, then find its IP address in the router or the maker's IP tool. A fixed address helps: reserve one for the machine in your router, so the same address opens it after a restart. No port has to be opened to the internet.
-
Point it at a pool
Open its dashboard and enter your Bitcoin pool address, worker name and password. Most pools write the worker as account.worker; solo pools often take your wallet address instead. Enter a second pool as a backup, change the default password of the dashboard, and save.
-
Check it is hashing
After a few minutes, check that hashrate, temperatures and fan speeds look normal. The pool shows the worker within a few minutes. Judge the hashrate by the pool’s 24-hour average, because the figure over minutes swings with luck. Write down the normal temperatures, so you notice later when they change.
Versions of the Antminer T17+
| Version | Hashrate | Power |
|---|---|---|
|
|
64 TH/s | 3,200 W |
|
|
61 TH/s | 3,050 W |
|
|
58 TH/s | 2,900 W |
|
|
55 TH/s | 2,750 W |
|
|
52 TH/s | 2,600 W |
Antminer T17+ setup questions
What room temperature does the Antminer T17+ need?
The maker rates it for 0 to 40 °C. Keep the hot exhaust away from the intake, because air that loops back raises chip temperatures and can trigger a shutdown.
What hashrate should the Antminer T17+ show?
Between 52 TH/s and 64 TH/s as an average over a day, depending on the version you have. The label on the machine names it; a lasting drop of a tenth or more points at heat, power or one hashboard.
How much heat does the Antminer T17+ give off?
All the power it draws leaves it as heat: 3,200 W is about 10,900 BTU an hour. Plan the ventilation or cooling of the room for that, all day.
What does the Antminer T17+ cost to run?
Its 3,200 W use about 2,304 kWh in 30 days. Multiply that by the price per kWh on your power bill: at $0.10 it is about $230, at $0.20 about $461. Hosted with us it is about $170 at $0.074, for 10–49 machines.
What does the Antminer T17+ mine?
It mines Bitcoin on the SHA-256 algorithm. Point it at a pool for that coin with your own payout address.