Pools and payouts
Rejected share
A rejected share is a share the pool refuses because it is invalid, duplicated, stale or below the required difficulty.
- Decided by
- the pool, share by share
- Comes with
- a reason code in the miner’s log
- Measured as
- rejected difficulty ÷ total difficulty
- Different from
- hardware errors, which never leave the machine
What it means in practice
A small reject rate is normal. A high or rising rate points to faulty hashboards, wrong pool settings, overheating or an unstable overclock. Monitoring reject rate per machine is one of the first checks when hashrate on the pool dashboard is below what the machine reports.
Finding the cause
Look at the reason the pool gives. “Stale” or “job not found” points to the network. “Low difficulty” or “above target” points to settings or the port. “Invalid” points to the machine: a chip running too fast or too hot.
Check one thing at a time, and give each change an hour before judging it.
The codes in the log
Most pools answer a refused share with a number and a few words. Code 21 is “job not found”, the late share. Code 22 is a duplicate: the same result was sent twice. Code 23 is “low difficulty share”. Code 24 is an unauthorized worker, which means the name or account is wrong. Code 25 means the machine sent work before it had subscribed.
Anything else arrives as code 20 with a text. Copy that text as it stands when you ask the pool for help. It usually tells their team more than a screenshot of the dashboard.
The codes are a convention from the first pools and not a strict standard. A few pools use numbers of their own, so when a code makes no sense, look at the pool’s help page first.
Hardware errors are counted elsewhere
A chip that runs too fast or too hot now and then reports a nonce that does not give the hash it claims. The control board checks each one and throws the wrong ones away. They show as HW or hardware errors on the machine’s own page and never reach the pool.
So a machine can have thousands of hardware errors and no rejected shares at all. The loss then appears as a lower hashrate. Read both lines: hardware errors describe the chips, rejects describe the conversation with the pool.
Working out the true rate
Counting shares can mislead, because the pool changes the difficulty while the machine runs. A handful of rejects at high difficulty can weigh more than a hundred small ones. Use the sum of difficulty where the page shows it.
Example figures: accepted difficulty in a day 3,900,000,000, rejected difficulty 100,000,000. 100 ÷ (3,900 + 100) = 2.5%. On a 200 TH/s machine that is the work of 5 TH/s. If the day before was 0.4%, something changed, and the first question is what.
When a proxy stands between
Farms often send many machines through one proxy that keeps a single connection to the pool. The proxy can refuse a share itself, or accept it and be refused later. A machine’s page may look clean while the pool’s page shows rejects for the proxy’s worker name.
Compare three numbers then: the machines’ accepted total, the proxy’s accepted total and the pool’s. The step where they part is the step to fix.
Worked example
A machine reports 200 TH/s but the pool credits 194 TH/s. The 6 TH/s gap is 6 / 200 = 3% and points to rejected or stale shares worth checking.
Example figures, not live data.
Common mistakes
- Reading the total since start-up, where one bad hour weeks ago still colors the figure.
- Changing the pool, the cable and the frequency on the same day, so no one knows which one helped.
- Pointing a machine at a pool for another algorithm and reading a full page of rejects as a fault.
Common questions
What reject rate is fine?
Around one percent or less. A sudden rise matters more than the level.
Do rejected shares cost money?
They earn nothing while the power was used, so it pays to bring the rate down.
Why do I get a few duplicate shares after a restart?
A machine or proxy may send the last results again when it reconnects. A handful is harmless. A steady stream points to firmware that should be updated.
My machine shows 100% rejected. What is wrong?
Almost always a setting: the wrong port, the wrong coin, a misspelled account or an address the pool does not accept. Check the pool line letter by letter first.
Can a wrong clock cause rejects?
It can. The header carries a time stamp, and a result with a time too far off is refused. Pools send the right time with each job, so this mostly appears on modified firmware.