Short-circuit rating, maximum (kA)
100
Arc ratings
up to 85 kAIC at 635 Vac; up to 100 kAIC at 508 Vac
Continuous current, maximum (A)
6,000

About the Eaton arc-resistant Magnum DS low-voltage switchgear

This is the arc-resistant version of Eaton's Magnum DS low-voltage switchgear. Switchgear is the main distribution point on the low-voltage side of a site. It takes power from the transformer and splits it into protected feeders through circuit breakers, so a fault on one feeder can be cleared without shutting down the rest.

This version is built to contain an arc flash inside the enclosure. Its arc ratings reach up to 85 kAIC at 635 Vac and up to 100 kAIC at 508 Vac. The lineup is rated for up to 6,000 A of continuous current and up to 100 kA of short-circuit current.

On a mining site, the switchgear feeds the PDUs and racks that run the miners. A large site has a lot of available fault current, and staff work near live gear during maintenance. Arc-resistant construction is aimed at that risk: it is designed to keep the energy of an internal arc away from people standing in front of the gear. The standard and front-access Magnum DS versions are listed separately. Ask us to size a lineup for your load.

What it holds

Capacity and performance

Arc ratings
up to 85 kAIC at 635 Vac; up to 100 kAIC at 508 Vac
Continuous current, maximum (A)
6,000

What your site needs

Power, cooling and space to plan before it arrives.

  • Power supply

    Short-circuit rating, maximum (kA)
    100

Where it fits

What this kind of equipment does on a mining site.

  • Built for mining sites

    Equipment for running many machines at once, sized by power and cooling rather than by single units.

  • Checked against your site

    Send your power, cooling and miner models, and we confirm the fit before you order.

  • Freight in the price

    Delivery to your site is included in the price shown.

In the box

  • One Eaton arc-resistant Magnum DS low-voltage switchgear

Warranty and returns

  • Ask us for this maker’s warranty terms before you order.
  • Something wrong? Write to us and we open the claim with the maker.
  • Cancel for a full refund until we process your order. After that it is final; faulty or wrong items are put right.

Eaton arc-resistant Magnum DS low-voltage switchgear: questions buyers ask

Ask us something else
What does switchgear do on a mining site?

It takes power from the transformer and splits it into protected feeders for the PDUs and miners, with breakers that can isolate a fault.

What are its arc ratings?

Up to 85 kAIC at 635 Vac and up to 100 kAIC at 508 Vac.

What current can it carry?

Up to 6,000 A continuous, with a short-circuit rating up to 100 kA.

How is it different from the front-access Magnum DS?

This version adds arc-resistant construction. The front-access version is built for service from the front and has a short-circuit rating up to 200 kAIC.

Is delivery included in the price of the Eaton arc-resistant Magnum DS low-voltage switchgear?

Yes. The price shown includes delivery. We confirm the dispatch date and freight route in writing with your order.

Can I get a quote for several Eaton arc-resistant Magnum DS low-voltage switchgear units?

Yes. Ask for a quote with the quantity and your site’s location, and a person replies with price, stock and a dispatch date.

How do I know the Eaton arc-resistant Magnum DS low-voltage switchgear fits my setup?

Send us your miner models, power supply and cooling. We check the fit against the specifications on this page before you order.

More in switchgear

  • Eaton

    Eaton Magnum DS low-voltage switchgear

    Short-circuit rating, maximum (kA)
    200
    Continuous current, maximum (A)
    10,000
    Voltage class, maximum (V)
    600

    Price on request

    View specs
  • Eaton

    Eaton front-access Magnum DS low-voltage switchgear

    Continuous current, maximum (A)
    6,000
    Voltage class, maximum (V)
    600
    Interrupting rating, maximum (kAIC)
    200

    Price on request

    View specs
  • Schneider Electric

    Square D QED-2 switchboard

    Standards
    CSA C22.2 No. 244, UL 891
    Custom rating, maximum (A)
    6,000
    System voltages
    208Y/120V, 480Y/277V, 600Y/347V

    Price on request

    View specs

Skip the build: host with us in Texas

A site needs transformers, cooling, a power contract and staff. Hosting with us starts at $0.074 per kWh for 10–49 machines, metered per machine, with your own pool account and wallet.