Eaton
Eaton arc-resistant Magnum DS low-voltage switchgear
- Short-circuit rating, maximum (kA)
- 100
- Arc ratings
- up to 85 kAIC at 635 Vac; up to…
- Continuous current, maximum (A)
- 6,000
Price on request
For mining sites and data halls that need a low-voltage switchgear line-up between the utility transformer and the miner power distribution.
Eaton Magnum DS is a family of low-voltage metal-enclosed switchgear: the cabinets of breakers that take power from a site transformer and split it into protected feeders. On a mining site it sits between the transformer and the power distribution units that feed the racks.
The line is built for systems up to 600 V class, with main bus ratings up to 10,000 A continuous and short-circuit ratings up to 200 kA. The number of sections, breaker sizes and bus rating are chosen for the load you plan to run.
Switchgear of this size is specified together with the transformer and the site's electrical design, and installed by licensed electricians. If you are planning a build-out, send us the load, voltage and layout and we will help you specify a line-up. Eaton also sells front-access and arc-resistant versions of Magnum DS for sites with tight floor space or stricter arc-flash rules.
Power, cooling and space to plan before it arrives.
What this kind of equipment does on a mining site.
Equipment for running many machines at once, sized by power and cooling rather than by single units.
Send your power, cooling and miner models, and we confirm the fit before you order.
Delivery to your site is included in the price shown.
Build your own site, buy one ready to mine, or run your fleet on our power.
Need the exact delivery scope or packing list? Ask us before you order
It is low-voltage switchgear for systems up to 600 V class, such as the 480 V and 415 V supplies common on mining sites.
Main bus ratings go up to 10,000 A continuous, with short-circuit ratings up to 200 kA. The rating of each line-up depends on how it is built.
The front-access version can stand against a wall because all service is from the front. The arc-resistant version is built to contain an internal arc fault. The standard version suits sites with room for rear access.
Yes. The price shown includes delivery. We confirm the dispatch date and freight route in writing with your order.
Yes. Ask for a quote with the quantity and your site’s location, and a person replies with price, stock and a dispatch date.
Send us your miner models, power supply and cooling. We check the fit against the specifications on this page before you order.
Eaton
Price on request
Eaton
Price on request
Schneider Electric
Price on request
A site needs transformers, cooling, a power contract and staff. Hosting with us starts at $0.074 per kWh for 10–49 machines, metered per machine, with your own pool account and wallet.