Power and wiring
220/240 V
220/240 V refers to the higher single-phase voltage that most ASIC miners need, rather than the 120 V of a standard US wall outlet.
- US homes
- 240 V between two live wires
- US shops and offices
- often 208 V between two phases
- Europe, much of Asia
- 230 V at the normal socket
- Common US plugs
- NEMA 6-20, 6-30, L6-30
- Effect of lower voltage
- more current for the same watts
What it means in practice
In a US home, 240 V comes from the two live wires of a split-phase supply and is used for appliances such as dryers and ovens. A miner on 240 V draws less current than it would on a lower voltage, so a dedicated 240 V circuit is usually the first change a home miner needs. Hashrate Index puts 240 V support at about 99% of ASIC miners, with some three-phase and hydro models as exceptions.
Getting a 240 V circuit for a miner
In the US an electrician adds a two-pole breaker, cable sized for the current and a receptacle that matches the miner’s cord. In Europe and most of Asia a normal socket already carries about 230 V, so the question there is the current the circuit can carry all day.
A miner is a continuous load. Plan for 125% of its current: a machine that draws 14.6 A at 240 V belongs on a 20 A circuit of its own.
Where the 240 volts come from
The transformer outside a US home has a winding with a tap in the middle. The tap is the neutral. From it to either end you measure 120 V, and from end to end 240 V. A miner’s supply connects to the two ends and needs no neutral, only the protective ground.
A commercial building with a 120/208 V system has three phases instead. Between any two of them there are 208 V. Miner supplies accept it, but the current is higher than at home. The same cord and breaker that were fine at 240 V may be too small there.
The same machine on three supplies
Example figures for a 3,500 W machine: 3,500 ÷ 240 = 14.6 A, 3,500 ÷ 230 = 15.2 A and 3,500 ÷ 208 = 16.8 A. With the 125% planning rule used in the US they become 18.2, 19.0 and 21.0 A.
On a 208 V supply that machine needs a 25 or 30 A circuit where 20 A was enough at 240 V. Always calculate with the voltage measured at the place, not with the number in the product title.
Voltage on a busy line
A long thin cable loses voltage along the way. Example figures: 100 feet of 12-gauge copper has about 0.4 ohm for the trip there and back. At 14.6 A that is 5.8 V lost, or 2.4%. The miner sees 234 V and the cable gives off about 85 W as heat.
If a machine restarts at random, measure at its plug while it runs. A reading that sags when neighbors or appliances start up points to the supply and not to the miner.
Using an existing outlet
A dryer or range outlet already carries 240 V. What matters is the breaker, the wire and whether anything else shares it. Example figures: a 30 A dryer circuit may carry 24 A all day, which is 5,760 W. The appliance must stay off while the miner runs.
The outlet’s shape seldom fits a miner’s cord. A licensed electrician can fit a receptacle or a small PDU that matches, which is safer than stacking adapters.
Whatever the outlet, measure twice: once with the machine off and once after an hour at full load. The second reading shows how stiff the supply really is.
Worked example
A 3,500 W miner draws 3,500 / 240 ≈ 14.6 A at 240 V and 3,500 / 220 ≈ 15.9 A at 220 V.
Example figures, not live data.
Common mistakes
- Trusting the color of a receptacle instead of measuring what it carries.
- Running a full-size machine through a step-up transformer from 120 V, where the wall circuit is far too small.
- Ordering a cord with the plug of another country.
Common questions
Can an ASIC miner run on 120 V?
Some home miners can. Full-size machines need 200 V or more, as their power supplies will not start below it.
Is 220 V the same as 240 V?
They are names for the same class of supply. The voltage at the socket sits between about 200 and 240 V by country and building, and miner power supplies accept the whole range.
Does a miner care which live wire is which?
No. A single-phase miner supply works either way round. The protective ground must always be connected.
Can I run a 230 V European miner in the US?
Usually yes. Miner supplies take both 50 and 60 Hz and a range such as 200 to 240 V. You only need the right cord. The label on the supply shows the range.
Is 277 V allowed?
Only where the power supply’s label says so. Some newer units accept it, and many stop at 264 V or lower.