Hardware and cooling
PSU (power supply unit)
The PSU converts mains AC power into the low-voltage DC that a miner's hashboards use.
- Turns
- AC mains into low-voltage DC
- Typical input
- 200 to 240 V single-phase
- Output
- About 12 to 15 V at very high current
- Efficiency
- Usually above 90%
- Cord types
- C13 or C19, sometimes two
What it means in practice
Its efficiency decides how much wall power is lost as heat before it reaches the chips. Its input rating decides what voltage and circuit the machine needs; most air-cooled ASICs run on 240 V single-phase input. A failing PSU is a common cause of a machine dropping offline.
What to match when replacing one
A replacement has to match the machine, not just the watts: the output voltage range, the connector or busbar to the hashboards, the signal cable the control board uses, and the input voltage. Makers give each unit a part number, such as the ones printed on Antminer and Whatsminer supplies; use that.
Before replacing it, check the cord, the breaker and the fan. Many “dead” supplies are a tripped breaker or a dusty fan.
What happens between plug and board
First the supply straightens the alternating current and shapes it so that the draw follows the voltage, a step called power factor correction. Then it switches that at high frequency through a small transformer and smooths the result into direct current. The control board tells it which voltage to deliver and reads back faults.
Startup is staged. The supply comes up, the control board checks the machine, and only then does the voltage for the hashboards rise. A click and a pause of a minute is normal.
Amps at 208 V and at 240 V
The machine needs watts, so a lower voltage means more current. Example figures: 3,500 W is 14.6 A at 240 V and 16.8 A at 208 V. In the United States a 20 A circuit is loaded to 16 A for continuous use, so the same machine fits on one and not on the other.
Many supplies also limit their output below a certain input voltage. On 208 V a machine may need a lower power mode or a 30 A circuit.
Cords count as well. A C19 connector is rated for more current than a C13, and a machine with two sockets needs both cords plugged in.
Two points of efficiency
Example figures: the boards need 3,290 W. A supply at 94% draws 3,500 W from the wall, and one at 96% draws 3,427 W. The difference of 73 W is 1.75 kWh a day, and it is also 73 W less heat inside the box.
Efficiency is best at around half to three quarters of the rating and falls a little near the top. A supply with headroom runs cooler and lasts longer.
Protection, and what a trip means
A supply switches itself off when the current is too high, the voltage strays or the inside is too hot. A brief off and on again clears a single event. One that repeats at the same load points to the board it feeds, the circuit or its own fan.
To tell them apart, start the machine with one hashboard connected, then two, then three, where the model allows it. If the supply trips when a particular board joins, look at that board.
Never open a supply. Capacitors inside hold a dangerous charge long after the plug is out. Circuits and sockets are work for a licensed electrician.
Worked example
A PSU that is 94% efficient, drawing 3,500 W from the wall, delivers 3,500 × 0.94 = 3,290 W to the hashboards and loses 210 W as heat.
Example figures, not live data.
Step by step
- Measure the voltage at the outlet, or ask an electrician to.
- Check cord, plug and breaker rating against the label.
- Clean the fan grille and listen for a steady fan.
- Read the log for a power or voltage error.
- Replace the unit with the same part number.
Common mistakes
- Using a computer’s C13 cord where the machine needs C19.
- Plugging two machines into one 20 A circuit.
- Replacing a supply by watts alone.
Common questions
Is the PSU included with a miner?
With most full-size and home miners, yes. Some small boards and older models take a separate one; the product page says so.
How do I know the PSU has failed?
No lights and no fan with good power at the cord, a restart loop, or an error code that names the power supply.
Can I run an ASIC supply on 120 V?
Full-size machines need 200 V or more. Small home miners have supplies made for 120 V.
Is power supply loss part of the rated watts?
Yes, when the rating is given at the wall, as makers usually do.
Why does the fan run when the miner is idle?
The supply cools itself and keeps a small standby voltage for the control board.